Mostrar o rexistro simple do ítem

dc.contributor.authorRicci, Matteo
dc.contributor.authorVicente-Samper, José María
dc.contributor.authorRomero Ante, Juan David
dc.contributor.authorEsteve, Vicente
dc.contributor.authorGarcía Aracil, Nicolás
dc.contributor.authorCordella, Francesca
dc.contributor.authorSabater-Navarro, José María
dc.date.accessioned2023-10-06T09:47:26Z
dc.date.available2023-10-06T09:47:26Z
dc.date.issued2023
dc.identifier.citationRicci, M., Vicente, J.M., Romero-Ante, J.D., Esteve, V., Garcia-Aracil, N., Cordella, F., Sabater-Navarro, J.M. 2023. Detección de apneas en recién nacidos utilizando una IMU abdominal. XLIV Jornadas de Automática, 99-104. https://doi.org/10.17979/spudc.9788497498609.099es_ES
dc.identifier.isbn978‐84‐9749‐860‐9
dc.identifier.urihttp://hdl.handle.net/2183/33558
dc.description.abstract[Resumen] En los últimos años, ha habido un aumento en los casos de colapso postnatal repentino en lactantes aparentemente sanos durante las primeras 24 horas de vida. Actualmente, los sistemas de monitoreo existentes no son capaces de detectar situaciones de apnea. En este trabajo, se propone un sistema que incluye un dispositivo electrónico para monitorear el movimiento abdominal generado por la respiración en recién nacidos y, una interfaz de usuario para el seguimiento de información. Se llevaron a cabo pruebas experimentales para validar el funcionamiento del sistema, tanto en posición supina como prona, así como en situaciones que involucraron el contacto entre la madre y el recién nacido. En general, los resultados obtenidos respaldan la viabilidad de utilizar dispositivos electrónicos de contacto directo como una alternativa prometedora para mejorar la detección de la respiración y la identificación de situaciones de apnea.es_ES
dc.description.abstract[Abstract] In recent years, there has been an increase in cases of sudden postnatal collapse in apparently healthy newborns within the first 24 hours of life. Currently, existing monitoring systems are unable to detect apnea situations. In this study, a system is proposed that includes an electronic device to monitor the abdominal movement generated by respiration in newborns, along with a user interface for information tracking. Experimental tests were conducted to validate the system’s performance in both supine and prone positions, as well as in situations involving mother-infant contact. Overall, the results support the feasibility of using direct contact electronic devices as a promising alternative to improve the detection of respiration and identify apnea situations.es_ES
dc.description.sponsorshipMinisterio de Ciencia e Innovación; PID2019-111023RB-C32es_ES
dc.language.isospaes_ES
dc.publisherUniversidade da Coruña. Servizo de Publicaciónses_ES
dc.relation.urihttps://doi.org/10.17979/spudc.9788497498609.099es_ES
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) https://creativecommons.org/licenses/by-nc-sa/4.0/es_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/es/*
dc.subjectApneaes_ES
dc.subjectColapso postnatal repentinoes_ES
dc.subjectIMUes_ES
dc.subjectRecién nacidoes_ES
dc.subjectRespiraciónes_ES
dc.subjectMonitorizaciónes_ES
dc.subjectSudden postnatal collapsees_ES
dc.subjectNewbornes_ES
dc.subjectRespirationes_ES
dc.subjectMonitoringes_ES
dc.titleDetección de apneas en recién nacidos utilizando una IMU abdominales_ES
dc.title.alternativeApnea detection in newborns using an abdominal IMUes_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.rights.accessinfo:eu-repo/semantics/openAccesses_ES
UDC.startPage99es_ES
UDC.endPage104es_ES
dc.identifier.doihttps://doi.org/10.17979/spudc.9788497498609.099
UDC.conferenceTitleXLIV Jornadas de Automáticaes_ES


Ficheiros no ítem

Thumbnail
Thumbnail

Este ítem aparece na(s) seguinte(s) colección(s)

Mostrar o rexistro simple do ítem