Detección de apneas en recién nacidos utilizando una IMU abdominal

Use this link to cite
http://hdl.handle.net/2183/33558
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) https://creativecommons.org/licenses/by-nc-sa/4.0/
Collections
Metadata
Show full item recordTitle
Detección de apneas en recién nacidos utilizando una IMU abdominalAlternative Title(s)
Apnea detection in newborns using an abdominal IMUAuthor(s)
Date
2023Citation
Ricci, M., Vicente, J.M., Romero-Ante, J.D., Esteve, V., Garcia-Aracil, N., Cordella, F., Sabater-Navarro, J.M. 2023. Detección de apneas en recién nacidos utilizando una IMU abdominal. XLIV Jornadas de Automática, 99-104. https://doi.org/10.17979/spudc.9788497498609.099
Abstract
[Resumen] En los últimos años, ha habido un aumento en los casos de colapso postnatal repentino en lactantes aparentemente sanos durante las primeras 24 horas de vida. Actualmente, los sistemas de monitoreo existentes no son capaces de detectar situaciones de apnea. En este trabajo, se propone un sistema que incluye un dispositivo electrónico para monitorear el movimiento abdominal generado por la respiración en recién nacidos y, una interfaz de usuario para el seguimiento de información. Se llevaron a cabo pruebas experimentales para validar el funcionamiento del sistema, tanto en posición supina como prona, así como en situaciones que involucraron el contacto entre la madre y el recién nacido. En general, los resultados obtenidos respaldan la viabilidad de utilizar dispositivos electrónicos de contacto directo como una alternativa prometedora para mejorar la detección de la respiración y la identificación de situaciones de apnea. [Abstract] In recent years, there has been an increase in cases of sudden postnatal collapse in apparently healthy newborns within the first 24 hours of life. Currently, existing monitoring systems are unable to detect apnea situations. In this study, a system is proposed that includes an electronic device to monitor the abdominal movement generated by respiration in newborns, along with a user interface for information tracking. Experimental tests were conducted to validate the system’s performance in both supine and prone positions, as well as in situations involving mother-infant contact. Overall, the results support the feasibility of using direct contact electronic devices as a promising alternative to improve the detection of respiration and identify apnea situations.
Keywords
Apnea
Colapso postnatal repentino
IMU
Recién nacido
Respiración
Monitorización
Sudden postnatal collapse
Newborn
Respiration
Monitoring
Colapso postnatal repentino
IMU
Recién nacido
Respiración
Monitorización
Sudden postnatal collapse
Newborn
Respiration
Monitoring
Editor version
Rights
Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) https://creativecommons.org/licenses/by-nc-sa/4.0/
ISBN
978‐84‐9749‐860‐9