Mostrar o rexistro simple do ítem

dc.contributor.authorGallego-Miguel, A.
dc.contributor.authorGarcía Haro, Juan Miguel
dc.contributor.authorBautista, S.
dc.contributor.authorSimon Rodriguez, M.A.
dc.contributor.authorVelasco-Fernández, Ana-I
dc.date.accessioned2022-09-06T07:26:29Z
dc.date.available2022-09-06T07:26:29Z
dc.date.issued2022
dc.identifier.citationGallego-Miguel, A., Garcia-Haro, J. M., Bautista, S., Simon Rodriguez, M. A., Velasco-Fernandez, A.I. (2022) Diseño y fabricación de una órtesis activa para descarga de peso. XLIII Jornadas de Automática: libro de actas, pp. 694-699. https://doi.org/10.17979/spudc.9788497498418.0694es_ES
dc.identifier.isbn978-84-9749-841-8
dc.identifier.urihttp://hdl.handle.net/2183/31499
dc.description.abstract[Resumen] Cada día, un mayor número de personas sufren algún tipo de accidente, que termina derivando en una reducción de la movilidad de alguna extremidad o parte del cuerpo humano. Como consecuencia, la calidad de vida de estas personas se ve considerablemente reducida. Particularmente, una patología asociada a esta situación es la osteocondritis disecante del astrágalo, la cual produce fuertes dolores cuando se apoya el peso del cuerpo sobre el tobillo. Para intentar prevenir o aliviar dicho dolor, este artículo se centra en el diseño, prototipado y comprobación de una órtesis de descarga. Dicho dispositivo no tiene como objetivo asistir en el movimiento de flexo-extensión del tobillo, como la mayoría de las soluciones existentes, sino en descargar de manera axial y redistribuir el peso de forma externa al tobillo. Con este planteamiento, a través de una serie de pruebas y cuestionarios, se ha ido verificando la evolución de los pacientes antes, durante y después de usar la órtesis.es_ES
dc.description.abstract[Abstract] Every day, a greater number of people suffer some type of accident, which ends up resulting in a reduction of the mobility of some limb or part of the human body. As a consequence, the quality of life of these people is considerably reduced. Particularly, a pathology associated with this situation is osteochondritis dissecans of the astragalus, which causes severe pain when the weight of the body is supported on the ankle. In an attempt to prevent or relieve such pain, this article focuses on the design, prototyping and testing of an unloading orthosis. This device does not aim to assist in the dorsiflexion ans plantarflexion movement of the ankle, as most existing solutions do. It pretends to offload axially and redistribute weight externally to the ankle. With this approach, through a series of tests and questionnaires, the evolution of the patients before, during and after using the orthosis has been verified.es_ES
dc.language.isospaes_ES
dc.publisherUniversidade da Coruña. Servizo de Publicaciónses_ES
dc.relation.urihttps://doi.org/10.17979/spudc.9788497498418.0694es_ES
dc.rightsAtribución-NoComercial-CompartirIgual 4.0 Internacional (CC BY-NC-SA 4.0) https://creativecommons.org/licenses/by-nc-sa/4.0/deed.eses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/es/*
dc.subjectOrtesises_ES
dc.subjectOsteocondritis disecantees_ES
dc.subjectMovilidad reducidaes_ES
dc.subjectRehabilitaciónes_ES
dc.subjectOrthosises_ES
dc.subjectOsteochondritis dissecanses_ES
dc.subjectAstragaluses_ES
dc.subjectReduced mobilityes_ES
dc.subjectRehabilitationes_ES
dc.titleDiseño y fabricación de una órtesis activa para descarga de pesoes_ES
dc.title.alternativeDesign and fabrication of an active orthosis for anckle weight reliefes_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.rights.accessinfo:eu-repo/semantics/openAccesses_ES
UDC.startPage694es_ES
UDC.endPage699es_ES
UDC.conferenceTitleXLIII Jornadas de Automáticaes_ES


Ficheiros no ítem

Thumbnail
Thumbnail

Este ítem aparece na(s) seguinte(s) colección(s)

Mostrar o rexistro simple do ítem