dc.contributor.author | Moura, Joaquim de | |
dc.contributor.author | Novo Buján, Jorge | |
dc.contributor.author | Penas, Susana | |
dc.contributor.author | Ortega Hortas, Marcos | |
dc.contributor.author | Silva, Jorge | |
dc.contributor.author | Mendonça, Ana Maria | |
dc.date.accessioned | 2024-06-07T12:42:47Z | |
dc.date.available | 2024-06-07T12:42:47Z | |
dc.date.issued | 2018 | |
dc.identifier.citation | J. de Moura, J. Novo, S. Penas, M. Ortega, J. Silva, and A. M. Mendonça, "Automatic Characterization of the serous Retinal Detachment Associated with the subretinal Fluid Presence in Optical Coherence Tomography Images", in 22nd International Conference on Knowledge-Based and Intelligent Information and Engineering Systems, KES 2018, Procedia Computer Science, Vol. 126, Pp. 244 - 253, doi: 10.1016/j.procS.2018.07.258 | es_ES |
dc.identifier.uri | http://hdl.handle.net/2183/36839 | |
dc.description | 22nd International Conference on Knowledge-Based and Intelligent Information and Engineering Systems, KES 2018, Belgrade, 3 September 2018 - 5 September 2018 | es_ES |
dc.description.abstract | [Abstract]: An accurate detection of the macular edema (ME) presence constitutes a crucial ophthalmological issue as it provides useful information for the identification, diagnosis and treatment of different relevant ocular and Systemic diseaseS. serous Retinal Detachment (sRD) is a particular type of ME, which is characterized by the leakage of fluid that has a propensity of being accumulated in the macular region. This paper proposes a new methodology for the automatic identification and characterization of the sRD edema using Optical Coherence Tomography (OCT) imageS. The subretinal fluids and the External Limiting Membrane (ELM) retinal layers are identified and characterized to measure the disease severity. Four different visualization modules were designed including representative derived parameters to facilitate the doctor's work in the diagnostic evaluation of ME. The different steps of this method were validated using the manual labelling provided by an expert clinician. The validation of the proposed method offered satisfactory results, constituting a suitable scenario with intuitive visual representations that also include different relevant biomarkerS. | es_ES |
dc.description.sponsorship | This work is supported by the Instituto de Salud Carlos III, Government of Spain and FEDER funds of the European Union through the PI14/02161 and the DTS15/00153 research projects and by the Ministerio de Economía y Competitividad, Government of Spain through the DPI2015-69948-R research project. Also, this work has received financial support from the European Union (European Regional Development Fund - ERDF) and the Xunta de Galicia, Centro singular de investigación de Galicia accreditation 2016-2019, Ref. ED431G/01; and Grupos de Referencia Competitiva, Ref. ED431C 2016-047. | es_ES |
dc.description.sponsorship | Xunta de Galicia; ED431G/01 | es_ES |
dc.description.sponsorship | Xunta de Galicia; ED431C 2016-047 | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Elsevier B.V. | es_ES |
dc.relation | info:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/PI14%2F02161/ES/DESARROLLO DE UN SISTEMA AUTOMÁTICO PARA EL CÁLCULO Y VISUALIZACIÓN DE PROPIEDADES ANATÓMICAS DE LA RETINA EN SD-OCT Y SU CORRELACIÓN CON ANÁLISIS FUNCIONALES HETEROGÉNEOS DE LA VISIÓN | es_ES |
dc.relation | info:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DTS15%2F00153/ES/SIRIUS - SISTEMA DE ANÁLISIS DE MICROCIRCULACIÓN RETINIANA: EVALUACIÓN MULTIDISCIPLINAR E INTEGRACIÓN EN PROTOCOLOS CLÍNICOS | es_ES |
dc.relation | info:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2015-69948-R/ES/IDENTIFICACION Y CARACTERIZACION DEL EDEMA MACULAR DIABETICO MEDIANTE ANALISIS AUTOMATICO DE TOMOGRAFIAS DE COHERENCIA OPTICA Y TECNICAS DE APRENDIZAJE MAQUINA | es_ES |
dc.relation.uri | https://doi.org/10.1016/j.procs.2018.07.258 | es_ES |
dc.rights | Attribution-NonCommercial-NoDerivs 4.0 International (CC BY-NC-ND 4.0) | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
dc.subject | Computer-aided diagnosis | es_ES |
dc.subject | diabetic macular edema | es_ES |
dc.subject | optical coherence tomography | es_ES |
dc.subject | Serous retinal detachment | es_ES |
dc.title | Automatic Characterization of the serous Retinal Detachment Associated with the subretinal Fluid Presence in Optical Coherence Tomography Images | es_ES |
dc.type | info:eu-repo/semantics/conferenceObject | es_ES |
dc.type | info:eu-repo/semantics/conferenceObject | es_ES |
dc.rights.access | info:eu-repo/semantics/openAccess | es_ES |
UDC.journalTitle | Procedia Computer Science | es_ES |
UDC.volume | 126 | es_ES |
UDC.startPage | 244 | es_ES |
UDC.endPage | 253 | es_ES |
dc.identifier.doi | 10.1016/j.procS.2018.07.258 | |
UDC.conferenceTitle | KES 2018 | es_ES |