Análise preliminar do potencial biomédico de receptores macrocíclicos orgánicos con resposta a estímulos I
Ver/ abrir
Use este enlace para citar
http://hdl.handle.net/2183/29162Coleccións
- Traballos académicos (FCIE) [1005]
Metadatos
Mostrar o rexistro completo do ítemTítulo
Análise preliminar do potencial biomédico de receptores macrocíclicos orgánicos con resposta a estímulos ITítulo(s) alternativo(s)
Análisis preliminar del potencial biomédico de receptores macrocíclicos orgánicos con respuesta a estímulos IPreliminary screening of stimuli‐responsive organic macrocyclic receptors for biomedical applications I
Autor(es)
Director(es)
Rey-Rico, AnaMartínez-Lage, Andrés
Data
2021Centro/Dpto/Entidade
Universidade da Coruña. Facultade de CienciasDescrición
Traballo fin de grao (UDC.CIE). Bioloxía. Curso 2020/2021Resumo
[Resumo] A síntese de novos receptores moleculares no eido da química supramolecular
experimentou un gran auxe nos últimos anos debido ás súas potenciais aplicacións
biolóxicas. En especial, os sistemas receptor-substrato presentan unha serie de
características interesantes para a súa aplicación en sistemas de liberación controlada de
fármacos, que van dende a súa capacidade de autoensamblaxe ata a resposta a
estímulos. Sen embargo, para o seu uso en biomedicina é necesario que amosen unha
boa biocompatibilidade. Trala síntese do ciclofano tetracatiónico red box – derivado do
coñecido blue box – e os bos resultados obtidos no estudo de complexos de inclusión,
prevese un elevado potencial no campo biomédico para este receptor. Neste traballo,
como unha aproximación inicial ás posibles aplicacións da red box, levouse a cabo unha
avaliación da súa biocompatibilidade en dúas liñas celulares – unha normal e unha tumoral –,e estimouse de xeito indirecto a cantidade internalizada mediante medidas de
absorbancia. Os resultados obtidos amosaron que o macrociclo presenta unha toxicidade
relativamente baixa en ambas liñas, cunha maior sensibilidade na liña non tumoral. [Resumen] experimentado un gran auge en los últimos años debido a sus potenciales aplicaciones
biológicas. En particular, los sistemas receptor-sustrato presentan una serie de
características interesantes para su aplicación en sistemas de liberación controlada de
fármacos, que van desde su capacidad de autoensamblaje hasta la respuesta a estímulos.
Sin embargo, para su uso en biomedicina es necesario que muestren una buena
biocompatibilidad. Tras la síntesis del ciclofano tetracatiónico red box- derivada de la
conocida blue box - y los buenos resultados obtenidos en el estudio de los complejos de
inclusión, se prevé un alto potencial en el campo biomédico para este receptor. En este
trabajo, como aproximación inicial a las posibles aplicaciones de la red box , se realizó una
evaluación de su biocompatibilidad en dos líneas celulares, una normal y una tumoral, y se
estimó indirectamente la cantidad internalizada mediante medidas de absorbancia. Los
resultados obtenidos mostraron que el macrociclo presenta una toxicidad relativamente
baja en ambas líneas, con una mayor sensibilidad en la línea no tumoral. [Abstract] The synthesis of new molecular receptors in the field of supramolecular chemistry has
experienced a great boom in recent years due to their potential biological applications. In
particular, host-guest systems present a number of interesting features for their application
in controlled drug delivery systems, ranging from their self-assembly capacity to their stimuli
responsivness. However, for their use in biomedicine it is necessary that they show good
biocompatibility. After the synthesis of the tetracathionic cyclophane red box - derived from
the well-known blue box - and the good results obtained in the study of inclusion
complexes, a high potential in the biomedical field is foreseen for this receptor. In this work,
as an initial approach to the possible applications of the red box, an evaluation of its
biocompatibility was carried out in two cell lines, one normal and one tumor, and the
amount internalized was indirectly estimated by absorbance measurements. The results
obtained showed that the macrocycle exhibits a relatively low toxicity in both lines, with a
higher sensitivity in the non-tumor line.
Palabras chave
Sistemas de liberación controlada de fármacos
Química supramolecular
Química receptor-substrato
Macrociclo
Red box
Biocompatibilidade
Viabilidade celular
Citotoxicidade
Transporte intracelular
Química receptor-sustrato
Biocompatibilidad
Viabilidad celula
Citotoxicidad
Controlled drug delivery systems
Supramolecular chemistry
Host-guest chemistry
Macrocycle
Macrocycle
Cell viability
Cytotoxicity
Intracellular transport
Química supramolecular
Química receptor-substrato
Macrociclo
Red box
Biocompatibilidade
Viabilidade celular
Citotoxicidade
Transporte intracelular
Química receptor-sustrato
Biocompatibilidad
Viabilidad celula
Citotoxicidad
Controlled drug delivery systems
Supramolecular chemistry
Host-guest chemistry
Macrocycle
Macrocycle
Cell viability
Cytotoxicity
Intracellular transport
Dereitos
Os titulares dos dereitos de propiedade intelectual autorizan a visualización do contido deste traballo a través de Internet, así como a súa reproducción, gravación en soporte informático ou impresión para o seu uso privado e/ou con fins de estudo e de investigación. En nengún caso se permite o uso lucrativo deste documento. Estos dereitos afectan tanto ó resumo do traballo como o seu contido Los titulares de los derechos de propiedad intelectual autorizan la visualización del contenido de este trabajo a través de Internet, así como su repoducción, grabación en soporte informático o impresión para su uso privado o con fines de investigación. En ningún caso se permite el uso lucrativo de este documento. Estos derechos afectan tanto al resumen del trabajo como a su contenido