Mostrar o rexistro simple do ítem
Dispositivo de monitorización postural para personas de la tercera edad con alto grado de sedentarismo
dc.contributor.author | Vermander, Patrick | |
dc.contributor.author | Pérez, Nerea | |
dc.contributor.author | Mancisidor, Aitziber | |
dc.contributor.author | Cabanes, Itziar | |
dc.date.accessioned | 2021-08-24T10:23:26Z | |
dc.date.available | 2021-08-24T10:23:26Z | |
dc.date.issued | 2021 | |
dc.identifier.citation | Vermander, P., Pérez, N., Mancisidor, A., Cabanes, I. Dispositivo de monitorización postural para personas de la tercera edad con alto grado de sedentarismo. En XLII Jornadas de Automática: libro de actas. Castelló, 1-3 de septiembre de 2021 (pp. 75-82). DOI capítulo: https://doi.org/10.17979/spudc.9788497498043.075 DOI libro: https://doi.org/10.17979/spudc.9788497498043 | es_ES |
dc.identifier.isbn | 978-84-9749-804-3 | |
dc.identifier.uri | http://hdl.handle.net/2183/28289 | |
dc.description.abstract | [Resumen] La monitorización postural en personas de la tercera edad es fundamental para evitar la aparición de problemas músculo-esqueléticos, así como la prevención de situaciones de riesgo y caídas. En este trabajo, se presenta un dispositivo de monitorización compuesto por 16 sensores FSR (Force Sensitive Resistor), colocados de forma discreta a lo largo del asiento y respaldo de una silla. La selección de la ubicación de estos sensores se ha llevado a cabo mediante un estudio previo, donde se han identificado los puntos más significativos. Para validar el dispositivo de monitorización, se han realizado diferentes ensayos experimentales donde se han comparado los resultados obtenidos mediante el dispositivo propuesto con los medidos con una malla de presión comercial. Los resultados muestran que las posturas presentadas quedan correctamente caracterizadas mediante el sistema propuesto, reduciendo el coste del sistema y aumentando su autonomía. | es_ES |
dc.description.abstract | [Abstract] Postural monitoring in the elderly is essential to avoid the appearance of musculoskeletal problems, as well as to prevent risky situations and falls. In this work, a monitoring device composed of 16 FSR (Force Sensitive Resistor) sensors is presented, discreetly placed along the seat and back of a chair. The selection of the location of these sensors has been carried out through a previous study, where the most significant points have been identified. To validate the monitoring device, different experimental tests have been carried out where the results obtained by the proposed device have been compared with those measured with a pressure mat. The results show that the positions presented are correctly characterized by the proposed system, being able to reduce the cost of the hardware and increase its autonomy. | es_ES |
dc.description.sponsorship | Este trabajo ha sido financiado por: FEDER/Ministerio de Ciencia e Innovación – Agencia Estatal de Investigación/Proyecto PID2020-112667RB-I00, la Universidad del País Vasco UPV/EHU (GIU19/045), así como por el contrato predoctoral PRE-2020-1-0073 del Gobierno Vasco | es_ES |
dc.description.sponsorship | Universidad del País Vasco/Euskal Herriko Unibertsitatea; GIU19/045 | es_ES |
dc.description.uri | https://doi.org/10.17979/spudc.9788497498043 | |
dc.language.iso | spa | es_ES |
dc.publisher | Universidade da Coruña, Servizo de Publicacións | es_ES |
dc.relation | info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2020-112667RB-I00/ES/ | |
dc.relation.uri | https://doi.org/10.17979/spudc.9788497498043.075 | es_ES |
dc.rights | Atribución-NoComercial-CompartirIgual 4.0 Internacional (CC BY-NC-SA 4.0) | es_ES |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/deed.es | * |
dc.subject | Análisis postural | es_ES |
dc.subject | Monitorización | es_ES |
dc.subject | Sedentarismo | es_ES |
dc.subject | Sensores de Fuerza | es_ES |
dc.subject | Postural analysis | es_ES |
dc.subject | Monitoring | es_ES |
dc.subject | Sedentary lifestyle | es_ES |
dc.subject | Force sensors | es_ES |
dc.title | Dispositivo de monitorización postural para personas de la tercera edad con alto grado de sedentarismo | es_ES |
dc.title.alternative | Postural Monitoring Device for Elderly With a High Degree of Sedentarism | es_ES |
dc.type | info:eu-repo/semantics/conferenceObject | es_ES |
dc.rights.access | info:eu-repo/semantics/openAccess | es_ES |
UDC.startPage | 75 | es_ES |
UDC.endPage | 82 | es_ES |
dc.identifier.doi | 10.17979/spudc.9788497498043.075 | |
UDC.conferenceTitle | XLII Jornadas de Automática | es_ES |