Gaia Early Data Release 3: The celestial reference frame (Gaia-CRF3)

Use este enlace para citar
http://hdl.handle.net/2183/32819Coleccións
- Investigación (FIC) [1654]
Metadatos
Mostrar o rexistro completo do ítemTítulo
Gaia Early Data Release 3: The celestial reference frame (Gaia-CRF3)Autor(es)
Data
2022-11-23Cita bibliográfica
S. A. Klioner et al., «Gaia Early Data Release 3: The celestial reference frame (Gaia-CRF3)», Astronomy and Astrophysics, vol. 667, 2022, doi: 10.1051/0004-6361/202243483.
Resumo
[Abstract]: Context. Gaia-CRF3 is the celestial reference frame for positions and proper motions in the third release of data from the Gaia mission, Gaia DR3 (and for the early third release, Gaia EDR3, which contains identical astrometric results). The reference frame is defined by the positions and proper motions at epoch 2016.0 for a specific set of extragalactic sources in the (E)DR3 catalogue.
Aims. We describe the construction of Gaia-CRF3 and its properties in terms of the distributions in magnitude, colour, and astrometric quality.
Methods. Compact extragalactic sources in Gaia DR3 were identified by positional cross-matching with 17 external catalogues of quasi-stellar objects (QSO) and active galactic nuclei (AGN), followed by astrometric filtering designed to remove stellar contaminants. Selecting a clean sample was favoured over including a higher number of extragalactic sources. For the final sample, the random and systematic errors in the proper motions are analysed, as well as the radio-optical offsets in position for sources in the third realisation of the International Celestial Reference Frame (ICRF3).
Results. Gaia-CRF3 comprises about 1.6 million QSO-like sources, of which 1.2 million have five-parameter astrometric solutions in Gaia DR3 and 0.4 million have six-parameter solutions. The sources span the magnitude range G = 13–21 with a peak density at 20.6 mag, at which the typical positional uncertainty is about 1 mas. The proper motions show systematic errors on the level of 12 µas yr–1 on angular scales greater than 15 deg. For the 3142 optical counterparts of ICRF3 sources in the S/X frequency bands, the median offset from the radio positions is about 0.5 mas, but it exceeds 4 mas in either coordinate for 127 sources. We outline the future of Gaia-CRF in the next Gaia data releases. Appendices give further details on the external catalogues used, how to extract information about the Gaia-CRF3 sources, potential (Galactic) confusion sources, and the estimation of the spin and orientation of an astrometric solution.
Palabras chave
Astrometry
Catalogs
Proper motions
Quasars: general
Reference systems
Catalogs
Proper motions
Quasars: general
Reference systems
Versión do editor
Dereitos
Atribución 3.0 España
ISSN
0004-6361
Ítems relacionados
Mostrando ítems relacionados por Título, autor ou materia.
-
Dispersal History of SARS-CoV-2 in Galicia, Spain
Gallego-García, Pilar; Estévez-Gómez, Nuria; De Chiara, Loretta; Alvariño, Pilar; Juiz-González, Pedro M.; Torres-Beceiro, Isabel; Poza, Margarita; Vallejo, J. A.; Rumbo-Feal, Soraya; Conde-Pérez, Kelly; Aja-Macaya, Pablo; Ladra, Susana; Moreno-Flores, Antonio; Gude-González, María J.; Coira, Amparo; Aguilera, Antonio; Costa-Alcalde, José J.; Trastoy, Rocío; Barbeito-Castiñeiras, Gema; García-Souto, Daniel; Tubío, José M. C.; Trigo-Daporta, Matilde; Camacho-Zamora, Pablo; García-Costa, Juan; González-Domínguez, María; Canoura-Fernández, Luis; Glez-Peña, Daniel; Pérez-Castro, Sonia; Cabrera, Jorge J.; Daviña-Núñez, Carlos; Godoy-Diz, Montserrat; Treinta-Álvarez, Ana Belén; Veiga, María Isabel; Sousa, Joao Carlos; Osório, Nuno S.; Comas, Iñaki; González-Candelas, Fernando; Hong, Samuel L.; Bollen, Nena; Dellicour, Simon; Baele, Guy; Suchard, Marc A.; Lemey, Philippe; Agulla, Andrés; Bou, Germán; Alonso-García, Pilar; Pérez-del-Molino, María Luisa; García-Campello, Marta; Paz-Vidal, Isabel; Regueiro, Benito; Posada, David (John Wiley & Sons, 2024-06-28)[Abstract] The dynamics of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) transmission are influenced by a variety of factors, including social restrictions and the emergence of distinct variants. In this ... -
La insuficiencia venosa crónica y sus manifestaciones en el pie
Arnáiz-García, María Elena; Arnáiz-García, Ana María; Alonso Peña, David; García-Martín, Aida; Arnáiz-García, Javier (Universidade da Coruña, 2017)[Abstract] Chronic venous insufficiency is a common condition that affects a large number of population, being a frequent reason for consultation with an important clinical, social and economic impact. Through this case ... -
Código shock cardiogénico 2023: documento de expertos para una organización multidisciplinaria que permita una atención de calidad
Martínez-Sellés, Manuel; Hernández-Pérez, Francisco José; Uribarri, Aitor; Martín Villén, Luis; Zapata, Luis; Alonso, Joaquín C.; Amat-Santos, Ignacio C.; Ariza-Solé, Albert; Barrabés, José A.; Barrio, José María; Canteli, Ángela; Alonso-Fernández-Gatta, Marta; Corbí Pascual, Miguel J.; Díaz, Domingo; Crespo-Leiro, María Generosa; de la Torre-Hernández, José María; Ferrera, Carlos; García González, Martín J.; García-Carreño, Jorge; García Guereta, Luis; García Quintana, Antonio; Jorge Pérez, Pablo; González-Juanatey, José Ramón; López de Sá, Esteban; Sánchez, Pedro Luis; Monteagudo, María; Palomo López, Nora; Reyes, Guillermo; Rosell, Fernando; Solla-Buceta, Miguel; Segovia-Cubero, Javier; Sionis Green, Alessandro; Stepanenko, Alexander; Iglesias Álvarez, Diego; Viana Tejedor, Ana; Voces, Roberto; Fuset Cabanes, María Paz; Gimeno Costa, José Ricardo; Díaz, José; Fernández-Avilés, Francisco (Elsevier, 2022-11-18)[Resumen] Pese a los esfuerzos realizados para mejorar la atención al shock cardiogénico (SC), incluyendo el desarrollo de dispositivos de asistencia circulatoria mecánica (ACM), su pronóstico continúa siendo desfavorable. ...