Mostrar o rexistro simple do ítem
Determination of Sr-90 in milk samples from the study of statistical results
dc.contributor.author | Otero Pazos, Alberto | |
dc.contributor.author | Calleja-García, Alfonso | |
dc.contributor.author | Fernández-Ibáñez, Isabel | |
dc.contributor.author | Rodríguez Gómez, Benigno Antonio | |
dc.contributor.author | Piñón-Pazos, A. | |
dc.contributor.author | Calvo-Rolle, José Luis | |
dc.date.accessioned | 2023-01-12T19:02:01Z | |
dc.date.available | 2023-01-12T19:02:01Z | |
dc.date.issued | 2017 | |
dc.identifier.citation | Otero-Pazos, A., Calleja-Garcia, A., Fernandez-Ibanez, M., Rodriguez-Gomez, B., Pinon-Pazos, A., & Calvo-Rolle, J. (2017). Determination of Sr-90 in milk samples from the study of statistical results. Nuclear Technology and Radiation Protection, 32(2), 185-191. https://doi.org/10.2298/NTRP1702185O | es_ES |
dc.identifier.issn | 1451-3994 | |
dc.identifier.uri | http://hdl.handle.net/2183/32340 | |
dc.description.abstract | [Abstract] The determination of 90Sr in milk samples is the main objective of radiation monitoring laboratories because of its environmental importance. In this paper the concentration of activity of 39 milk samples was obtained through radiochemical separation based on selective retention of Sr in a cationic resin (Dowex 50WX8, 50-100 mesh) and subsequent determination by a low-level proportional gas counter. The results were checked by performing the measurement of the Sr concentration by using the flame atomic absorption spectroscopy technique, to finally obtain the mass of 90Sr. From the data obtained a statistical treatment was performed using linear regressions. A reliable estimate of the mass of 90Sr was obtained based on the gravimetric technique, and secondly, the counts per minute of the third measurement in the 90Sr and 90Y equilibrium, without having to perform the analysis. These estimates have been verified with 19 milk samples, obtaining overlapping results. The novelty of the manuscript is the possibility of determining the concentration of 90Sr in milk samples, without the need to perform the third measurement in the equilibrium. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Vinča Institute of Nuclear Science | es_ES |
dc.relation.uri | https://doi.org/10.2298/NTRP1702185O | es_ES |
dc.rights | Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 Serbia (CC BY NC ND) https://creativecommons.org/licenses/by-nc-nd/3.0/rs/deed.en | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
dc.subject | Strontium | es_ES |
dc.subject | Proportional counter | es_ES |
dc.subject | Flame atomic absorption spectroscopy | es_ES |
dc.subject | Linear regression | es_ES |
dc.subject | Radiochemical separation | es_ES |
dc.title | Determination of Sr-90 in milk samples from the study of statistical results | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.rights.access | info:eu-repo/semantics/openAccess | es_ES |
UDC.journalTitle | Nuclear Technology and Radiation Protection | es_ES |
UDC.volume | 32 | es_ES |
UDC.issue | 2 | es_ES |
UDC.startPage | 185 | es_ES |
UDC.endPage | 191 | es_ES |
dc.identifier.doi | https://doi.org/10.2298/NTRP1702185O |
Ficheiros no ítem
Este ítem aparece na(s) seguinte(s) colección(s)
-
GI-CTC - Artigos [80]