Mostrar o rexistro simple do ítem

dc.contributor.authorFerreiro, Borja
dc.contributor.authorAndrade-Garda, José Manuel
dc.contributor.authorLópez-Mahía, P.
dc.contributor.authorMuniategui, Soledad
dc.contributor.authorVázquez, Cristina
dc.contributor.authorPérez, Andrés
dc.contributor.authorRey, María
dc.contributor.authorVales Fernández, Carlos
dc.date.accessioned2021-11-10T09:52:04Z
dc.date.available2021-11-10T09:52:04Z
dc.date.issued2021-07-28
dc.identifier.citationFerreiro B, Andrade J, López-Mahía P, et al. Fast quality control of natural gas for commercial supply and transport utilities. Fuel 2021;305:121500. doi:https://doi.org/10.1016/j.fuel.2021.121500.es_ES
dc.identifier.issn0016-2361
dc.identifier.urihttp://hdl.handle.net/2183/28832
dc.descriptionFinanciado para publicación en acceso aberto: Universidade da Coruña/CISUGes_ES
dc.description.abstract[Abstract] Quality control of natural gas frequently relies on off-line slow standardized chromatographic techniques. Previous implementations of new measurement approaches focused of synthetic mixtures without extensive industrial validation. Here, a fast alternative based on infrared spectra is presented to predict the gas constituents and a physical parameter, the Wobbe index. Commercial samples instead of synthetic mixtures were used to develop predictive models. Method performance parameters were calculated and ca. 100 % of the sample-specific confidence intervals for the predictions overlapped with those of the reference values and the approach was unbiased and precise. The limits of detection and quantification (classical and considering errors of type I and II) outperformed other approaches. Validation included commercial samples and primary mixtures. Furthermore, prediction models considering reduced sets of variables were sought for using Markov-chain Monte Carlo guided searches (uninformative variable elimination and random frog) and common (iPLS, UVE and SR) approaches. The prediction errors and limits of detection of these ‘reduced’ models outperformed those from other approaches. The methodology takes only minutes to analyse a sample, requires few sample and no reagents (only some argon), making this approach cost-effective and environmentally-friendly.es_ES
dc.description.sponsorshipXunta de Galicia; ED431C-2017/28es_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.relation.urihttps://doi.org/10.1016/j.fuel.2021.121500es_ES
dc.rightsAtribución-NoComercial-SinDerivadas 4.0 Internacionales_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectNatural gas compositiones_ES
dc.subjectWobbe indexes_ES
dc.subjectInfrared gas measurementes_ES
dc.subjectPLS predictiones_ES
dc.subjectSpectral variable selectiones_ES
dc.titleFast Quality Control of Natural Gas for Commercial Supply and Transport Utilitieses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessinfo:eu-repo/semantics/openAccesses_ES
UDC.journalTitleFueles_ES
UDC.volume305es_ES
UDC.startPage121500es_ES
dc.identifier.doi10.1016/j.fuel.2021.121500


Ficheiros no ítem

Thumbnail
Thumbnail

Este ítem aparece na(s) seguinte(s) colección(s)

Mostrar o rexistro simple do ítem