Mostrar o rexistro simple do ítem

dc.contributor.authorMazoteras-Pardo, Victoria
dc.contributor.authorBecerro-de-Bengoa-Vallejo, Ricardo
dc.contributor.authorLosa Iglesias, Marta Elena
dc.contributor.authorMartínez Jiménez, Eva María
dc.contributor.authorCalvo-Lobo, César
dc.contributor.authorRomero Morales, Carlos
dc.contributor.authorLópez-López, Daniel
dc.contributor.authorPalomo-López, Patricia
dc.date.accessioned2020-09-16T13:57:31Z
dc.date.available2020-09-16T13:57:31Z
dc.date.issued2020-07
dc.identifier.citationMazoteras-Pardo V, Becerro-De-Bengoa-Vallejo R, Losa-Iglesias ME, Martínez-Jiménez EM, Calvo-Lobo C, Romero-Morales C, López-López D, Palomo-López P QardioArm Blood Pressure Monitoring in a Population With Type 2 Diabetes: Validation Study J Med Internet Res 2020;22(7):e19781 DOI: 10.2196/19781es_ES
dc.identifier.issn1438-8871
dc.identifier.urihttp://hdl.handle.net/2183/26195
dc.description.abstract[Abstract] Background: Home blood pressure monitoring has many benefits, even more so, in populations prone to high blood pressure, such as persons with diabetes. Objective: The purpose of this research was to validate the QardioArm mobile device in a sample of individuals with noninsulin-dependent type 2 diabetes in accordance with the guidelines of the second International Protocol of the European Society of Hypertension. Methods: The sample consisted of 33 patients with type 2 diabetes. To evaluate the validity of QardioArm by comparing its data with that obtained with a digital sphygmomanometer (Omron M3 Intellisense), two nurses collected diastolic blood pressure, systolic blood pressure, and heart rate with both devices. Results: The analysis indicated that the test device QardioArm met all the validation requirements using a sample population with type 2 diabetes. Conclusions: This paper reports the first validation of QardioArm in a population of individuals with noninsulin-dependent type 2 diabetes. QardioArm for home monitoring of blood pressure and heart rate met the requirements of the second International Protocol of the European Society of Hypertension.es_ES
dc.language.isoenges_ES
dc.publisherJMIR Publicationses_ES
dc.relation.urihttps://doi.org/10.2196/19781es_ES
dc.rightsAtribución 4.0 Internacionales_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectBlood pressurees_ES
dc.subjectHypertensiones_ES
dc.subjectType 2 diabeteses_ES
dc.subjectMobile applicationses_ES
dc.subjectSoftware validationes_ES
dc.titleQardioArm Blood Pressure Monitoring in a Population With Type 2 Diabetes: Validation Studyes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessinfo:eu-repo/semantics/openAccesses_ES
UDC.journalTitleJournal of Medical Internet Researches_ES
UDC.volume22es_ES
UDC.issue7es_ES


Ficheiros no ítem

Thumbnail
Thumbnail

Este ítem aparece na(s) seguinte(s) colección(s)

Mostrar o rexistro simple do ítem