Mostrar o rexistro simple do ítem

dc.contributor.authorEstévez-Cimadevila, Javier
dc.contributor.authorSuárez-Riestra, Félix
dc.contributor.authorOtero-Chans, Dolores
dc.contributor.authorMartín-Gutiérrez, Emilio
dc.date.accessioned2020-03-23T12:04:33Z
dc.date.available2020-03-23T12:04:33Z
dc.date.issued2018
dc.identifier.citationEstévez-Cimadevila, J., F. Suárez-Riestra, D. Otero-Chans, and E. Martín-Gutiérrez. “Experimental Analysis of Pretensioned CLT-Glulam T-Section Beams.” Advances in Materials Science and Engineering 2018 (2018): 1–12. doi:10.1155/2018/1528792es_ES
dc.identifier.urihttp://hdl.handle.net/2183/25212
dc.description.abstractThe bending behavior of T-section beams composed of a glulam web and an upper cross-laminated timber flange was studied. The influence of two fundamental factors on the bending strength and stiffness was considered: the wood species used for the webs and pretensioning with unbonded tendons. Sixteen specimens with a 9 m span were tested until failure: eight of them were non- tensioned (4 Picea abies webs and 4 Quercus robur webs) and the other eight were pretensioned using threaded bars with 20 mm diameter anchored in plates fixed at the ends of the specimens (4 Picea abies webs and 4 Quercus robur webs). Pretensioning with unbonded tendons showed a clear improvement in the load capacity of the specimens with Picea abies webs, while the difference was not significant for the specimens with Quercus robur webs. Considering deflection, pretensioning gave the advantage of an initial precamber but also generated slight variations in the stiffness as a result of increasing the portion of the section that was in compression. The variation in the stiffness depended on the relation between the compressive and tensile moduli of elasticity parallel to the grain, and its influence on the deflection was analyzed using a finite element method.es_ES
dc.language.isoenges_ES
dc.relation.urihttps://doi.org/10.1155/2018/1528792es_ES
dc.rightsAtribución 4.0 Internacionales_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectPrestressinges_ES
dc.subjectPretensioninges_ES
dc.subjectGlulames_ES
dc.subjectCLTes_ES
dc.subjectTimber flooringes_ES
dc.subjectWooden structureses_ES
dc.titleExperimental analysis of pretensioned CLT-glulam T-section beamses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessinfo:eu-repo/semantics/openAccesses_ES
UDC.journalTitleAdvances in Materials Science and Engineeringes_ES
UDC.issueArticle ID 1528792es_ES
UDC.startPage1es_ES
UDC.endPage12es_ES


Ficheiros no ítem

Thumbnail
Thumbnail

Este ítem aparece na(s) seguinte(s) colección(s)

Mostrar o rexistro simple do ítem