Mostrar o rexistro simple do ítem

dc.contributor.authorTerán Baamonde, Javier
dc.contributor.authorAndrade-Garda, José Manuel
dc.contributor.authorSoto-Ferreiro, Rosa-María
dc.contributor.authorCarlosena, Alatzne
dc.contributor.authorPrada-Rodríguez, Darío
dc.date.accessioned2015-10-21T13:53:59Z
dc.date.available2015-10-21T13:53:59Z
dc.date.issued2015-05
dc.identifier.citationTerán-Baamonde J, Andrade JM, Soto-Ferreiro RM, Carlosena A, Prada D. A simple procedure to select a model for mass discrimination correction in isotope dilution inductively coupled plasma mass spectrometry. J Anal At Spectrom 2015;30(5):1197-1206. http://dx.doi.org/10.1039/c4ja00475bes_ES
dc.identifier.issn0267-9477
dc.identifier.urihttp://hdl.handle.net/2183/15402
dc.description.abstract[Abstract] A fast, simple and straightforward procedure to decide on the best model to calculate the mass discrimination factor in Isotope Dilution Inductively Coupled Plasma Mass Spectrometry (ID-ICP-MS) is proposed. It is based on the study of the residuals of the different models that are proposed commonly, viz., the linear, the exponential, the power and Russell's models. However, it can be generalized to evaluate any model proposed to linearize the relationship between the theoretical/measured isotope ratios and the mass. The procedure does not involve laboratory extra work, it is rooted on basic statistics associated with the least squares fit, and can be applied easily by the analysts so that decision making is fast and reliable. The procedure was exemplified with four different examples where Cd, Cr, Nd and Sm were determined by ID-ICP-MS.es_ES
dc.description.sponsorshipXunta de Galicia; GRC2013-047es_ES
dc.language.isoenges_ES
dc.publisherRoyal Society of Chemistryes_ES
dc.relation.urihttp://dx.doi.org/10.1039/c4ja00475bes_ES
dc.rightsReconocimiento-NoComercial-SinObraDerivada 4.0 Internacional
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectIsotope dilution inductively coupled plasma mass spectrometryes_ES
dc.subjectLeast squares fites_ES
dc.subjectID-ICP-MSes_ES
dc.subjectMass discrimination correctiones_ES
dc.subjectResidualses_ES
dc.subjectLinearizationes_ES
dc.subjectMass discrimination factores_ES
dc.titleA Simple Procedure to Select a Model for Mass Discrimination Correction in Isotope Dilution Inductively Coupled Plasma Mass Spectrometryes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessinfo:eu-repo/semantics/openAccesses_ES


Ficheiros no ítem

Thumbnail
Thumbnail
Thumbnail
Thumbnail

Este ítem aparece na(s) seguinte(s) colección(s)

Mostrar o rexistro simple do ítem