Use this link to cite:
https://hdl.handle.net/2183/49845 Polymer Coating Adhesion Drives Functional and Biological Outcomes in Meniscus Implants
Loading...
Identifiers
Publication date
Authors
Blanco, Alfonso F.
Rubio Prego, Inés
Bao-Varela, Carmen
Núñez Bernal, Paulina
Levato, Riccardo
Malda, Jos
Kon, Elizaveta
Crecente-Campo, José
Alonso, M. J.
Advisors
Other responsabilities
Journal Title
Bibliographic citation
Alfonso F. Blanco, Inés Rubio-Prego, Carmen Bao-Varela, Rebeca Bouza, Paulina Nuñez Bernal, Riccardo Levato, Jos Malda, Elizaveta Kon, José Crecente-Campo, María José Alonso; Polymer Coating Adhesion Drives Functional and Biological Outcomes in Meniscus Implants. ACS Appl. Mater. Interfaces 2026; https://doi.org/10.1021/acsami.6c10220
Type of academic work
Academic degree
Abstract
[Abstract]: Achieving stable integration of drug-releasing polymer coatings with load-bearing meniscus implants remains a challenge in biomaterials engineering. In this study, four surface modification strategies, femtosecond-pulsed laser treatment, oxygen plasma, polydopamine, and an ethyl-2-cyanoacrylate (ECA) interlayer, were evaluated for the integration of a dexamethasone (DEX)- and celecoxib (CLX)-releasing bilayer coating with a polycarbonate urethane (PCU) meniscus implant. The selected construct comprised an ECA interlayer applied from a 40% (w/v) solution, a CLX-loaded PLLA/PCL layer prepared at 100 mg/mL and a 53/47 (w/w) polymer ratio with 16.6% CLX loading, and an outer DEX-loaded PLGA layer prepared at 200 mg/mL with 2.44% DEX loading. At 37 °C, compared with uncoated PCU, ECA-containing constructs showed significantly higher storage modulus, loss modulus, and elastic modulus (p < 0.05), while tan δ remained unchanged, indicating preservation of the elastic-dominant viscoelastic response of the complete construct. The ECA-containing coating was subsequently adapted to the geometry of a sheep meniscus implant using an optimized dip-coating procedure. During a 21-day bioreactor study, repeated compression and shear increased cumulative DEX release from 59 to 67% and CLX release from 25 to 40% relative to static controls, while no visible
coating delamination was observed. Ethylene oxide sterilization preserved drug loading and release behavior. In an exploratory threemonth sheep study, the fiber-fixed coated implants remained in position, and the coating remained macroscopically associated with the retrieved prostheses. These findings support the use of an ECA interlayer to integrate a bilayer drug-releasing coating with a PCU meniscus implant while preserving construct-level mechanical behavior and drug release under the conditions evaluated.
Description
Editor version
Rights
Attribution 4.0 International