Polymer Coating Adhesion Drives Functional and Biological Outcomes in Meniscus Implants
| UDC.coleccion | Investigación | |
| UDC.departamento | Física e Ciencias da Terra | |
| UDC.grupoInv | Grupo de Polímeros | |
| UDC.institutoCentro | CITENI - Centro de Investigación en Tecnoloxías Navais e Industriais | |
| UDC.journalTitle | ACS Applied Materials & Interfaces | |
| dc.contributor.author | Blanco, Alfonso F. | |
| dc.contributor.author | Rubio Prego, Inés | |
| dc.contributor.author | Bao-Varela, Carmen | |
| dc.contributor.author | Bouza, Rebeca | |
| dc.contributor.author | Núñez Bernal, Paulina | |
| dc.contributor.author | Levato, Riccardo | |
| dc.contributor.author | Malda, Jos | |
| dc.contributor.author | Kon, Elizaveta | |
| dc.contributor.author | Crecente-Campo, José | |
| dc.contributor.author | Alonso, M. J. | |
| dc.date.accessioned | 2026-10-19T17:43:10Z | |
| dc.date.available | 2026-10-19T17:43:10Z | |
| dc.date.issued | 2026-10-09 | |
| dc.description.abstract | [Abstract]: Achieving stable integration of drug-releasing polymer coatings with load-bearing meniscus implants remains a challenge in biomaterials engineering. In this study, four surface modification strategies, femtosecond-pulsed laser treatment, oxygen plasma, polydopamine, and an ethyl-2-cyanoacrylate (ECA) interlayer, were evaluated for the integration of a dexamethasone (DEX)- and celecoxib (CLX)-releasing bilayer coating with a polycarbonate urethane (PCU) meniscus implant. The selected construct comprised an ECA interlayer applied from a 40% (w/v) solution, a CLX-loaded PLLA/PCL layer prepared at 100 mg/mL and a 53/47 (w/w) polymer ratio with 16.6% CLX loading, and an outer DEX-loaded PLGA layer prepared at 200 mg/mL with 2.44% DEX loading. At 37 °C, compared with uncoated PCU, ECA-containing constructs showed significantly higher storage modulus, loss modulus, and elastic modulus (p < 0.05), while tan δ remained unchanged, indicating preservation of the elastic-dominant viscoelastic response of the complete construct. The ECA-containing coating was subsequently adapted to the geometry of a sheep meniscus implant using an optimized dip-coating procedure. During a 21-day bioreactor study, repeated compression and shear increased cumulative DEX release from 59 to 67% and CLX release from 25 to 40% relative to static controls, while no visible coating delamination was observed. Ethylene oxide sterilization preserved drug loading and release behavior. In an exploratory threemonth sheep study, the fiber-fixed coated implants remained in position, and the coating remained macroscopically associated with the retrieved prostheses. These findings support the use of an ECA interlayer to integrate a bilayer drug-releasing coating with a PCU meniscus implant while preserving construct-level mechanical behavior and drug release under the conditions evaluated. | |
| dc.description.sponsorship | This project has received funding from the European Union’s Horizon 2020 research and innovation program under Grant Agreement No. 814444 (MEFISTO). Alfonso F. Blanco has received research support through a predoctoral grant from Xunta de Galicia, Grant No. ED481A 2022/066. Inés RubioPrego acknowledges a grant (IFI23/00035) from Instituto de Salud Carlos III “Contratos i-PFIS: Doctorados IIS-empresa en Ciencias y Tecnologías de la Salud”. Carmen Bao-Varela acknowledges financial support under grant PID2022- 138322OB-100 funded by MCIN/ AEI/ 10.13039/ 501100011033 and by “ERDF A way of making Europe” and the support of Xunta under grant ED431B 2023/07. The graphical artwork was created by the authors. BioRender (www.biorender.com) was used as a graphical design tool for the figures indicated in the corresponding captions. | |
| dc.description.sponsorship | Xunta de Galicia; ED481A 2022/066 | |
| dc.description.sponsorship | Xunta de Galicia; ED431B 2023/07 | |
| dc.identifier.citation | Alfonso F. Blanco, Inés Rubio-Prego, Carmen Bao-Varela, Rebeca Bouza, Paulina Nuñez Bernal, Riccardo Levato, Jos Malda, Elizaveta Kon, José Crecente-Campo, María José Alonso; Polymer Coating Adhesion Drives Functional and Biological Outcomes in Meniscus Implants. ACS Appl. Mater. Interfaces 2026; https://doi.org/10.1021/acsami.6c10220 | |
| dc.identifier.doi | 10.1021/acsami.6c10220 | |
| dc.identifier.issn | 1944-8252 | |
| dc.identifier.uri | https://hdl.handle.net/2183/49845 | |
| dc.language.iso | eng | |
| dc.publisher | ACS | |
| dc.relation.projectID | info:eu-repo/grantAgreement/EC/H2020/814444 | |
| dc.relation.projectID | info:eu-repo/grantAgreement/ISCIII/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/IFI23%2F00035 | |
| dc.relation.projectID | info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/PID2022-138322OB-100/ES/MICROFLUIDIC DEVICES IN FLEXIBLE AND ELASTIC MATERIALS FOR FLOW-GUIDED THERAPY | |
| dc.relation.uri | https://doi.org/10.1021/acsami.6c10220 | |
| dc.rights | Attribution 4.0 International | en |
| dc.rights.accessRights | open access | |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
| dc.subject | Meniscus prosthesis | |
| dc.subject | Drug-releasing coating | |
| dc.subject | Polycarbonate urethane | |
| dc.subject | PCU | |
| dc.subject | Coating adhesion | |
| dc.subject | Osteoarthritis | |
| dc.title | Polymer Coating Adhesion Drives Functional and Biological Outcomes in Meniscus Implants | |
| dc.type | journal article | |
| dc.type.hasVersion | VoR | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 57ec8477-70c6-4e07-aa99-531b6d3342dc | |
| relation.isAuthorOfPublication.latestForDiscovery | 57ec8477-70c6-4e07-aa99-531b6d3342dc |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Blanco_AlfonsoF_2026_Polymer-coating-adhesion-drives-functional-and-biological-outcomes-in-meniscus-implants.pdf
- Size:
- 13.89 MB
- Format:
- Adobe Portable Document Format

