Polymer Coating Adhesion Drives Functional and Biological Outcomes in Meniscus Implants

UDC.coleccionInvestigación
UDC.departamentoFísica e Ciencias da Terra
UDC.grupoInvGrupo de Polímeros
UDC.institutoCentroCITENI - Centro de Investigación en Tecnoloxías Navais e Industriais
UDC.journalTitleACS Applied Materials & Interfaces
dc.contributor.authorBlanco, Alfonso F.
dc.contributor.authorRubio Prego, Inés
dc.contributor.authorBao-Varela, Carmen
dc.contributor.authorBouza, Rebeca
dc.contributor.authorNúñez Bernal, Paulina
dc.contributor.authorLevato, Riccardo
dc.contributor.authorMalda, Jos
dc.contributor.authorKon, Elizaveta
dc.contributor.authorCrecente-Campo, José
dc.contributor.authorAlonso, M. J.
dc.date.accessioned2026-10-19T17:43:10Z
dc.date.available2026-10-19T17:43:10Z
dc.date.issued2026-10-09
dc.description.abstract[Abstract]: Achieving stable integration of drug-releasing polymer coatings with load-bearing meniscus implants remains a challenge in biomaterials engineering. In this study, four surface modification strategies, femtosecond-pulsed laser treatment, oxygen plasma, polydopamine, and an ethyl-2-cyanoacrylate (ECA) interlayer, were evaluated for the integration of a dexamethasone (DEX)- and celecoxib (CLX)-releasing bilayer coating with a polycarbonate urethane (PCU) meniscus implant. The selected construct comprised an ECA interlayer applied from a 40% (w/v) solution, a CLX-loaded PLLA/PCL layer prepared at 100 mg/mL and a 53/47 (w/w) polymer ratio with 16.6% CLX loading, and an outer DEX-loaded PLGA layer prepared at 200 mg/mL with 2.44% DEX loading. At 37 °C, compared with uncoated PCU, ECA-containing constructs showed significantly higher storage modulus, loss modulus, and elastic modulus (p < 0.05), while tan δ remained unchanged, indicating preservation of the elastic-dominant viscoelastic response of the complete construct. The ECA-containing coating was subsequently adapted to the geometry of a sheep meniscus implant using an optimized dip-coating procedure. During a 21-day bioreactor study, repeated compression and shear increased cumulative DEX release from 59 to 67% and CLX release from 25 to 40% relative to static controls, while no visible coating delamination was observed. Ethylene oxide sterilization preserved drug loading and release behavior. In an exploratory threemonth sheep study, the fiber-fixed coated implants remained in position, and the coating remained macroscopically associated with the retrieved prostheses. These findings support the use of an ECA interlayer to integrate a bilayer drug-releasing coating with a PCU meniscus implant while preserving construct-level mechanical behavior and drug release under the conditions evaluated.
dc.description.sponsorshipThis project has received funding from the European Union’s Horizon 2020 research and innovation program under Grant Agreement No. 814444 (MEFISTO). Alfonso F. Blanco has received research support through a predoctoral grant from Xunta de Galicia, Grant No. ED481A 2022/066. Inés RubioPrego acknowledges a grant (IFI23/00035) from Instituto de Salud Carlos III “Contratos i-PFIS: Doctorados IIS-empresa en Ciencias y Tecnologías de la Salud”. Carmen Bao-Varela acknowledges financial support under grant PID2022- 138322OB-100 funded by MCIN/ AEI/ 10.13039/ 501100011033 and by “ERDF A way of making Europe” and the support of Xunta under grant ED431B 2023/07. The graphical artwork was created by the authors. BioRender (www.biorender.com) was used as a graphical design tool for the figures indicated in the corresponding captions.
dc.description.sponsorshipXunta de Galicia; ED481A 2022/066
dc.description.sponsorshipXunta de Galicia; ED431B 2023/07
dc.identifier.citationAlfonso F. Blanco, Inés Rubio-Prego, Carmen Bao-Varela, Rebeca Bouza, Paulina Nuñez Bernal, Riccardo Levato, Jos Malda, Elizaveta Kon, José Crecente-Campo, María José Alonso; Polymer Coating Adhesion Drives Functional and Biological Outcomes in Meniscus Implants. ACS Appl. Mater. Interfaces 2026; https://doi.org/10.1021/acsami.6c10220
dc.identifier.doi10.1021/acsami.6c10220
dc.identifier.issn1944-8252
dc.identifier.urihttps://hdl.handle.net/2183/49845
dc.language.isoeng
dc.publisherACS
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/H2020/814444
dc.relation.projectIDinfo:eu-repo/grantAgreement/ISCIII/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/IFI23%2F00035
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/PID2022-138322OB-100/ES/MICROFLUIDIC DEVICES IN FLEXIBLE AND ELASTIC MATERIALS FOR FLOW-GUIDED THERAPY
dc.relation.urihttps://doi.org/10.1021/acsami.6c10220
dc.rightsAttribution 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectMeniscus prosthesis
dc.subjectDrug-releasing coating
dc.subjectPolycarbonate urethane
dc.subjectPCU
dc.subjectCoating adhesion
dc.subjectOsteoarthritis
dc.titlePolymer Coating Adhesion Drives Functional and Biological Outcomes in Meniscus Implants
dc.typejournal article
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublication57ec8477-70c6-4e07-aa99-531b6d3342dc
relation.isAuthorOfPublication.latestForDiscovery57ec8477-70c6-4e07-aa99-531b6d3342dc

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Blanco_AlfonsoF_2026_Polymer-coating-adhesion-drives-functional-and-biological-outcomes-in-meniscus-implants.pdf
Size:
13.89 MB
Format:
Adobe Portable Document Format