Use this link to cite:
http://hdl.handle.net/2183/28385 Desarrollo de un exoesqueleto para el antebrazo y la muñeca utilizando un solo actuador
Loading...
Identifiers
Publication date
Authors
Álvarez-Pastor, Jesús
Lledó Pérez, Luis Daniel
Ezquerro, Santiago
Garrote, Alicia
Costa, Teresa
Blanco, A.
García Pérez, José Vicente
García-Aracil, Nicolás
Advisors
Other responsabilities
Journal Title
Bibliographic citation
Álvarez-Pastor, J., Lledó, L. D., Ezquerro, S., Garrote, A., Costa, T., Blanco, A., García-Pérez, J. V.; García-Aracil, N. Desarrollo de un exoesqueleto para el antebrazo y la muñeca utilizando un solo actuador. En XLII Jornadas de Automática: libro de actas. Castelló, 1-3 de septiembre de 2021 (pp.521-527). DOI capítulo: https://doi.org/10.17979/spudc.9788497498043.521 DOI libro: https://doi.org/10.17979/spudc.9788497498043
Type of academic work
Academic degree
Abstract
[Resumen] Las previsiones más recientes determinan que el número de accidentes cerebrovasculares serán esenciales para acelerar la recuperación del paciente el empleo de nuevas terapias de rehabilitación asistidas por sistemas robóticos.
Este artículo describe el diseño, desarrollo y control de un exoesqueleto ligero para el antebrazo y la muñeca utilizando un único actuador. Además, se ha llevado a cabo un estudio piloto con pacientes en el Hospital la Pedrera de Dénia
con el objetivo de analizar la usabilidad del sistema, y los resultados se recogen en el presente estudio.
[Abstract] Recent research states that the number of strokes will increase in the future. For this reason, it is paramount to introduce new rehabilitation therapies to accelerate the recovery of the patient. This article describes the design, development and control of a light exoskeleton for the forearm and wrist using a single actuator. Furthermore, a pilot study has been done with patients in La Pedrera Hospital in Denia to analyse the system’s usability. The results are presented in this study.
[Abstract] Recent research states that the number of strokes will increase in the future. For this reason, it is paramount to introduce new rehabilitation therapies to accelerate the recovery of the patient. This article describes the design, development and control of a light exoskeleton for the forearm and wrist using a single actuator. Furthermore, a pilot study has been done with patients in La Pedrera Hospital in Denia to analyse the system’s usability. The results are presented in this study.
Description
Editor version
Rights
Atribución-NoComercial-CompartirIgual 4.0 Internacional
https://creativecommons.org/licenses/by-nc-sa/4.0/deed.es


