Highly relaxing gadolinium based MRI contrast agents responsive to Mg2+ sensing
| UDC.coleccion | Investigación | es_ES |
| UDC.departamento | Química | es_ES |
| UDC.endPage | 4087 | es_ES |
| UDC.grupoInv | Reactividade Química e Fotorreactividade (REACT!) | es_ES |
| UDC.issue | 34 | es_ES |
| UDC.journalTitle | Chemical Communications | es_ES |
| UDC.startPage | 4085 | es_ES |
| UDC.volume | 48 | es_ES |
| dc.contributor.author | Abada, Sabah | |
| dc.contributor.author | Lecointre, Alexandre | |
| dc.contributor.author | Elhabiri, Mourad | |
| dc.contributor.author | Esteban-Gómez, David | |
| dc.contributor.author | Platas-Iglesias, Carlos | |
| dc.contributor.author | Tallec, Gaylord | |
| dc.contributor.author | Mazzanti, Marinella | |
| dc.contributor.author | Charbonnière, Loïc J. | |
| dc.date.accessioned | 2018-11-26T11:32:39Z | |
| dc.date.available | 2018-11-26T11:32:39Z | |
| dc.date.issued | 2012-04-28 | |
| dc.description.abstract | [Abstract] A Gd complex based on a polyphosphonated pyridyl ligand shows a very high stability in aqueous solution (logKEuL = 25.7), a high relaxivity (8.5 mM−1 s−1 at 25 °C and 20 MHz) and a marked and selective relaxivity enhancement (37%) in the presence of Mg2+, opening interesting perspectives for the design of cation responsive contrast agents. | es_ES |
| dc.identifier.citation | Highly relaxing gadolinium based MRI contrast agents responsive to Mg2+ sensing. S. Abada, A. Lecointre, M. Elhabiri, D. Esteban-Gómez, C. Platas-Iglesias, G. Tallec, M. Mazzanti and L. J. Charbonnière, Chem. Commun., 2012, 48, 4085–4087. | es_ES |
| dc.identifier.issn | 1359-7345 | |
| dc.identifier.issn | 1364-548X | |
| dc.identifier.uri | http://hdl.handle.net/2183/21354 | |
| dc.language.iso | eng | es_ES |
| dc.publisher | Royal Society of Chemistry | es_ES |
| dc.relation.uri | https://doi.org/10.1039/C2CC30757J | es_ES |
| dc.rights.accessRights | open access | es_ES |
| dc.subject | MRI contrast agents | es_ES |
| dc.subject | DFT calculations | es_ES |
| dc.subject | Gadolinium complexes | es_ES |
| dc.subject | Relaxivity | es_ES |
| dc.subject | Magnesium sensing | es_ES |
| dc.title | Highly relaxing gadolinium based MRI contrast agents responsive to Mg2+ sensing | es_ES |
| dc.type | journal article | es_ES |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | f30c18a2-108e-44d6-a7d2-b3b4e378509b | |
| relation.isAuthorOfPublication | 8bb35ae5-5c53-4d41-87b8-949a82445202 | |
| relation.isAuthorOfPublication.latestForDiscovery | f30c18a2-108e-44d6-a7d2-b3b4e378509b |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- EstebanGomez_David_2012_Highly_relaxing_gadolinium_based_MRI_contrast_agents_responsive_Mg2+_sensing.pdf
- Size:
- 683.84 KB
- Format:
- Adobe Portable Document Format
- Description:

