A Sensorized 3D-Printed Knee Test Rig for Preliminary Experimental Validation of Patellar Tracking and Contact Simulation

UDC.coleccionInvestigación
UDC.departamentoEnxeñaría Naval e Industrial
UDC.grupoInvLaboratorio de Enxeñaría Mecánica (LIM)
UDC.institutoCentroCITENI - Centro de Investigación en Tecnoloxías Navais e Industriais
UDC.issue10
UDC.journalTitleSensors
UDC.startPages24103042
UDC.volume21
dc.contributor.authorMichaud, Florian
dc.contributor.authorMouzo, Francisco
dc.contributor.authorDopico, Daniel
dc.contributor.authorCuadrado, Javier
dc.date.accessioned2026-11-24T16:27:20Z
dc.date.available2026-11-24T16:27:20Z
dc.date.issued2024-05-10
dc.description.abstract[Abstract]: Experimental validation of computational simulations is important because it provides empirical evidence to verify the accuracy and reliability of the simulated results. This validation ensures that the simulation accurately represents real-world phenomena, increasing confidence in the model’s predictive capabilities and its applicability to practical scenarios. The use of musculoskeletal models in orthopedic surgery allows for objective prediction of postoperative function and optimization of results for each patient. To ensure that simulations are trustworthy and can be used for predictive purposes, comparing simulation results with experimental data is crucial. Although progress has been made in obtaining 3D bone geometry and estimating contact forces, validation of these predictions has been limited due to the lack of direct in vivo measurements and the economic and ethical constraints associated with available alternatives. In this study, an existing commercial surgical training station was transformed into a sensorized test bench to replicate a knee subject to a total knee replacement. The original knee inserts of the training station were replaced with personalized 3D-printed bones incorporating their corresponding implants, and multiple sensors with their respective supports were added. The recorded movement of the patella was used in combination with the forces recorded by the pressure sensor and the load cells, to validate the results obtained from the simulation, which was performed by means of a multibody dynamics formulation implemented in a custom-developed library. The utilization of 3D-printed models and sensors facilitated cost-effective and replicable experimental validation of computational simulations, thereby advancing orthopedic surgery while circumventing ethical concerns.
dc.description.sponsorshipThis work was funded by Pixee Medical under project OTR0123. Moreover, F. Michaud would like to acknowledge the support of the Galician Government and the Ferrol Industrial Campus by means of the postdoctoral research contract 2022/CP/048
dc.description.sponsorshipXunta de Galicia; 2022/CP/048
dc.identifier.citationDopico, D.; Cuadrado, J. A Sensorized 3D-Printed Knee Test Rig for Preliminary Experimental Validation of Patellar Tracking and Contact Simulation. Sensors 2024, 24, 3042. https://doi.org/10.3390/s24103042
dc.identifier.doi10.3390/s24103042
dc.identifier.issn1424-8220
dc.identifier.urihttps://hdl.handle.net/2183/50383
dc.language.isoeng
dc.publisherMDPI
dc.relation.urihttps://doi.org/10.3390/s24103042
dc.rightsAttribution 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectExperimental validation
dc.subjectMusculoskeletal modeling
dc.subjectContact simulation
dc.subjectKnee simulator
dc.subjectMultibody dynamics
dc.subjectContact forces
dc.subjectPatellar tracking
dc.subject3D printing
dc.subjectOrthopedic surgery
dc.subjectMotion capture
dc.titleA Sensorized 3D-Printed Knee Test Rig for Preliminary Experimental Validation of Patellar Tracking and Contact Simulation
dc.typejournal article
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublication9ae321fb-7c78-4cb9-a919-c21ae7ee1ab0
relation.isAuthorOfPublication89aa9ac6-b208-45ea-adc0-1198ce2f0f6e
relation.isAuthorOfPublicationc20ab7a3-b7bb-49b1-a8e8-d215f3213698
relation.isAuthorOfPublication2e638887-48a4-49dd-9a45-6060a48d7aab
relation.isAuthorOfPublication.latestForDiscovery9ae321fb-7c78-4cb9-a919-c21ae7ee1ab0

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Michau_Florian_2024_A_Sensorized_3D-Printed_Knee_Test Rig_for_Preliminary_Experimental_Validation.pdf
Size:
3.62 MB
Format:
Adobe Portable Document Format