Lower Back Injury Prevention and Sensitization of Hip Hinge with Neutral Spine Using Wearable Sensors during Lifting Exercises

UDC.coleccionInvestigaciónes_ES
UDC.departamentoEnxeñaría Naval e Industriales_ES
UDC.grupoInvLaboratorio de Enxeñaría Mecánica (LIM)es_ES
UDC.issue16es_ES
UDC.journalTitleSensorses_ES
UDC.volume21es_ES
dc.contributor.authorMichaud, Florian
dc.contributor.authorPérez Soto, Manuel
dc.contributor.authorLugrís-Armesto, Urbano
dc.contributor.authorCuadrado, Javier
dc.date.accessioned2021-09-21T17:02:32Z
dc.date.available2021-09-21T17:02:32Z
dc.date.issued2021-08
dc.description.abstract[Abstract] The popularization and industrialization of fitness over the past decade, with the rise of big box gyms and group classes, has reduced the quality of the basic formation and assessment of practitioners, which has increased the risk of injury. For most lifting exercises, a universal recommendation is maintaining a neutral spine position. Otherwise, there is a risk of muscle injury or, even worse, of a herniated disc. Maintaining the spine in a neutral position during lifting exercises is difficult, as it requires good core stability, a good hip hinge and, above all, observation of the posture in order to keep it correct. For this reason, in this work the authors propose the prevention of lumbar injuries with two inertial measurement units. The relative rotation between two sensors was measured for 39 voluntary subjects during the performance of two lifting exercises: the American kettlebell swing and the deadlift. The accuracy of the measurements was evaluated, especially in the presence of metals and for fast movements, by comparing the obtained results with those from an optical motion capture system. Finally, in order to develop a tool for improving sport performance and preventing injury, the authors analyzed the recorded motions, seeking to identify the most relevant parameters for good and safe lifting execution.es_ES
dc.description.sponsorshipThis work was funded by the Spanish MCI under project number PGC2018-095145-B-I00, co-financed by the EU through the EFRD program, and by the Galician Government under grant numbers ED431C2019/29 and IN853B-2018/02.es_ES
dc.description.sponsorshipXunta de Galicia; ED431C 2019/29
dc.description.sponsorshipXunta de Galicia; IN853B-2018/02
dc.identifier.citationMichaud, F.; Pérez Soto, M.; Lugrís, U.; Cuadrado, J. Lower Back Injury Prevention and Sensitization of Hip Hinge with Neutral Spine Using Wearable Sensors during Lifting Exercises. Sensors 2021, 21, 5487. https://doi.org/10.3390/s21165487
dc.identifier.doi10.3390/s21165487
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/2183/28493
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PGC2018-095145-B-I00/ES/ESTUDIO DE LA RELACION ENTRE EFICIENCIA Y NIVEL DE DETALLE EN MODELOS BIOMECANICOS DEL CUERPO HUMANO
dc.relation.urihttps://doi.org/10.3390/s21165487es_ES
dc.rightsAtribución 4.0 Internacional (CC BY 4.0)es_ES
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subjectInjury preventiones_ES
dc.subjectSport performancees_ES
dc.subjectLifting exerciseses_ES
dc.subjectMotion capturees_ES
dc.subjectInertial sensor
dc.titleLower Back Injury Prevention and Sensitization of Hip Hinge with Neutral Spine Using Wearable Sensors during Lifting Exerciseses_ES
dc.typejournal articlees_ES
dspace.entity.typePublication
relation.isAuthorOfPublication9ae321fb-7c78-4cb9-a919-c21ae7ee1ab0
relation.isAuthorOfPublication27a382bf-5c39-425c-84ea-43eace4efdff
relation.isAuthorOfPublication2e638887-48a4-49dd-9a45-6060a48d7aab
relation.isAuthorOfPublication.latestForDiscovery9ae321fb-7c78-4cb9-a919-c21ae7ee1ab0

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
sensors-21-05487-v2.pdf
Size:
5.52 MB
Format:
Adobe Portable Document Format
Description: