Determination of Sr-90 in milk samples from the study of statistical results

UDC.coleccionInvestigaciónes_ES
UDC.departamentoEnxeñaría Industriales_ES
UDC.endPage191es_ES
UDC.grupoInvCiencia e Técnica Cibernética (CTC)es_ES
UDC.issue2es_ES
UDC.journalTitleNuclear Technology and Radiation Protectiones_ES
UDC.startPage185es_ES
UDC.volume32es_ES
dc.contributor.authorOtero Pazos, Alberto
dc.contributor.authorCalleja-García, Alfonso
dc.contributor.authorFernández-Ibáñez, Isabel
dc.contributor.authorRodríguez Gómez, Benigno Antonio
dc.contributor.authorPiñón-Pazos, A.
dc.contributor.authorCalvo-Rolle, José Luis
dc.date.accessioned2023-01-12T19:02:01Z
dc.date.available2023-01-12T19:02:01Z
dc.date.issued2017
dc.description.abstract[Abstract] The determination of 90Sr in milk samples is the main objective of radiation monitoring laboratories because of its environmental importance. In this paper the concentration of activity of 39 milk samples was obtained through radiochemical separation based on selective retention of Sr in a cationic resin (Dowex 50WX8, 50-100 mesh) and subsequent determination by a low-level proportional gas counter. The results were checked by performing the measurement of the Sr concentration by using the flame atomic absorption spectroscopy technique, to finally obtain the mass of 90Sr. From the data obtained a statistical treatment was performed using linear regressions. A reliable estimate of the mass of 90Sr was obtained based on the gravimetric technique, and secondly, the counts per minute of the third measurement in the 90Sr and 90Y equilibrium, without having to perform the analysis. These estimates have been verified with 19 milk samples, obtaining overlapping results. The novelty of the manuscript is the possibility of determining the concentration of 90Sr in milk samples, without the need to perform the third measurement in the equilibrium.es_ES
dc.identifier.citationOtero-Pazos, A., Calleja-Garcia, A., Fernandez-Ibanez, M., Rodriguez-Gomez, B., Pinon-Pazos, A., & Calvo-Rolle, J. (2017). Determination of Sr-90 in milk samples from the study of statistical results. Nuclear Technology and Radiation Protection, 32(2), 185-191. https://doi.org/10.2298/NTRP1702185Oes_ES
dc.identifier.doihttps://doi.org/10.2298/NTRP1702185O
dc.identifier.issn1451-3994
dc.identifier.urihttp://hdl.handle.net/2183/32340
dc.language.isoenges_ES
dc.publisherVinča Institute of Nuclear Sciencees_ES
dc.relation.urihttps://doi.org/10.2298/NTRP1702185Oes_ES
dc.rightsCreative Commons Attribution-NonCommercial-NoDerivatives 3.0 Serbia (CC BY NC ND) https://creativecommons.org/licenses/by-nc-nd/3.0/rs/deed.enes_ES
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subjectStrontiumes_ES
dc.subjectProportional counteres_ES
dc.subjectFlame atomic absorption spectroscopyes_ES
dc.subjectLinear regressiones_ES
dc.subjectRadiochemical separationes_ES
dc.titleDetermination of Sr-90 in milk samples from the study of statistical resultses_ES
dc.typejournal articlees_ES
dspace.entity.typePublication
relation.isAuthorOfPublicationcb6ba2ec-1bee-44d2-b57c-d4fb47e3a65e
relation.isAuthorOfPublicationc68abce3-47ea-4c3b-ac34-6d271844a42f
relation.isAuthorOfPublication0973e46f-54fd-4bf9-8e0f-3c0c955fe550
relation.isAuthorOfPublication6981883a-51de-42e8-9dfc-35a78626fd7b
relation.isAuthorOfPublication89839e9c-9a8a-4d27-beb7-476cfab8965e
relation.isAuthorOfPublication.latestForDiscoverycb6ba2ec-1bee-44d2-b57c-d4fb47e3a65e

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2017_Otero-Pazos_Alberto_Determination_of_Sr-90_in_milk_samples.pdf
Size:
274.1 KB
Format:
Adobe Portable Document Format
Description: