Influence of the Biomechanical Evaluation of Rupture Using Two Shapes of Same Intramedullary Implant After Proximal Interphalangeal Joint Arthrodesis to Correct the Claw/ Hammer Pathology: A Finite Element Study

UDC.coleccionInvestigación
UDC.departamentoCiencias da Saúde
UDC.grupoInvGrupo de Investigación Saúde e Podoloxía (GISAP)
UDC.institutoCentroCIF - Campus Industrial de Ferrol
UDC.issue8
UDC.journalTitleInternational Wound Journal
UDC.startPagee70014
UDC.volume21
dc.contributor.authorLópez-López, Daniel
dc.contributor.authorBecerro-de-Bengoa-Vallejo, Ricardo
dc.contributor.authorBayod-López, Javier
dc.contributor.authorPrados-Frutos, Juan Carlos
dc.contributor.authorLosa-Iglesias, Marta Elena
dc.contributor.authorPrados-Privado, María
dc.date.accessioned2026-11-05T10:51:39Z
dc.date.available2026-11-05T10:51:39Z
dc.date.issued2024-08
dc.descriptionFinanciado para publicación en acceso aberto: Universidade da Coruña/CISUG
dc.description.abstract[Abstract] We used finite element analysis to study the mechanical stress distribution of a new intramedullary implant used for proximal interphalangeal joint (PIPJ) arthrodesis (PIPJA) to surgically correct the claw-hammer toe deformity that affects 20% of the population. After geometric reconstruction of the foot skeleton from claw toe images of a 36-year-old male patient, two implants were positioned, in the virtual model, one neutral implant (NI) and another one 10° angled (10°AI) within the PIPJ of the second through fourth HT during the toe-off phase of gait and results were compared to those derived for the non-surgical foot (NSF). A PIPJA was performed on the second toe using a NI reduced tensile stress at the proximal phalanx (PP) (45.83 MPa) compared to the NSF (59.44 MPa; p < 0.001). When using the 10°AI, the tensile stress was much higher at PP and middle phalanges (MP) of the same toe, measuring 147.58 and 160.58 MPa, respectively, versus 59.44 and 74.95 MPa at corresponding joints in the NSF (all p < 0.001). Similar results were found for compressive stresses. The NI reduced compressive stress at the second PP (-65.12 MPa) compared to the NSF (-113.23 MPa) and the 10°AI (-142 MPa) (all p < 0.001). The von Mises stresses within the implant were also significantly lower when using NI versus 10°AI (p < 0.001). Therefore, we do not recommend performing a PIPJA using the 10°AI due to the increase in stress concentration primarily at the second PP and MP, which could promote implant breakage.
dc.identifier.citationBayod-López J, Becerro-de-Bengoa-Vallejo R, Prados-Frutos JC, Losa-Iglesias M, López-López D, Prados-Privado M. Influence of the biomechanical evaluation of rupture using two shapes of same intramedullary implant after proximal interphalangeal joint arthrodesis to correct the claw/hammer pathology: A finite element study. Int Wound J. 2024 Aug;21(8):e70014. doi: 10.1111/iwj.70014.
dc.identifier.doi10.1111/iwj.70014
dc.identifier.urihttps://hdl.handle.net/2183/50125
dc.language.isoeng
dc.publisherJohn Wiley & Sons Ltd.
dc.relation.urihttps://doi.org/10.1111/iwj.70014
dc.rightsAttribution-NonCommercial 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.subjectFoot
dc.subjectFoot deformities
dc.subjectFoot diseases
dc.subjectMusculoskeletal diseases
dc.titleInfluence of the Biomechanical Evaluation of Rupture Using Two Shapes of Same Intramedullary Implant After Proximal Interphalangeal Joint Arthrodesis to Correct the Claw/ Hammer Pathology: A Finite Element Study
dc.typejournal article
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublication80e827fb-79b5-45af-9756-581db1fa7b73
relation.isAuthorOfPublication.latestForDiscovery80e827fb-79b5-45af-9756-581db1fa7b73

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LopezLopez_Daniel_2024_Influence_Biomechanical_Evaluation.pdf
Size:
6.15 MB
Format:
Adobe Portable Document Format