Breath gas concentrations mirror exposure to sevoflurane and isopropyl alcohol in hospital environments in non-occupational conditions

UDC.coleccionInvestigación
UDC.departamentoFisioterapia, Medicina e Ciencias Biomédicas
UDC.grupoInvEnfermidades Cerebrovasculares: Neuroloxía Clínica e Traslacional (INIBIC)
UDC.institutoCentroINIBIC - Instituto de Investigacións Biomédicas de A Coruña
UDC.issue1
UDC.journalTitleJournal of Breath Research
UDC.startPage016001
UDC.volume10
dc.contributor.authorCastellanos, María del Mar
dc.contributor.authorXifra, Gemma
dc.contributor.authorFernández-Real, José M.
dc.contributor.authorSánchez, Juan Manuel
dc.date.accessioned2026-07-02T11:18:43Z
dc.date.available2026-07-02T11:18:43Z
dc.date.issued2016-01-29
dc.description.abstract[Abstract] Anaesthetic gases and disinfectants are a primary source of air contamination in hospitals. A highly sensitive sorbent-trap methodology has been used to analyse exhaled breath samples with detection limits in the pptv range, which allows volatile organic compounds (VOCs) to be detected at significantly lower levels (5-6 orders of magnitude below) than the recommended exposure limits by different organizations. Two common VOCs used in hospital environments, isopropyl alcohol (IPA) and sevoflurane, have been evaluated. Forced-expiratory breath samples were obtained from 100 volunteers (24 hospital staff, 45 hospital visitors and 31 external controls). Significant differences for IPA were found between samples from volunteers who had not been in contact with hospital environments (mean value of 8.032 ppbv) and people staying (20.981 ppbv, p = 0.0002) or working (19.457 ppbv, p = 0.000 09) in such an environment. Sevoflurane, an anaesthetic gas routinely used as an inhaled anaesthetic, was detected in all samples from volunteers in the hospital environment but not in volunteers who had not been in recent contact with a hospital environment. The levels of sevoflurane were significantly higher (p = 0.000 24) among staff members (0.522 ppbv) than among visitors to the hospital (0.196 ppbv). We conclude that highly sensitive methods are required to detect anaesthetic gas contamination in hospital environments.
dc.identifier.citationCastellanos M, Xifra G, Fernández-Real JM, Sánchez JM. Breath gas concentrations mirror exposure to sevoflurane and isopropyl alcohol in hospital environments in non-occupational conditions. J Breath Res. 2016 Jan 29;10(1):016001.
dc.identifier.doi10.1088/1752-7155/10/1/016001
dc.identifier.issn1752-7163
dc.identifier.urihttps://hdl.handle.net/2183/48736
dc.language.isoeng
dc.publisherIOP Publishing
dc.relation.urihttps://doi.org/10.1088/1752-7155/10/1/016001
dc.rights.accessRightsopen access
dc.subject2-Propanol
dc.subjectAir Pollutants, Occupational
dc.subjectAnesthetics, Inhalation
dc.subjectMethyl Ethers
dc.subjectVolatile Organic Compounds
dc.titleBreath gas concentrations mirror exposure to sevoflurane and isopropyl alcohol in hospital environments in non-occupational conditions
dc.typejournal article
dc.type.hasVersionAM
dspace.entity.typePublication
relation.isAuthorOfPublicationfea87394-0be5-482f-b650-543f2240258c
relation.isAuthorOfPublication.latestForDiscoveryfea87394-0be5-482f-b650-543f2240258c

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Castellanos_Breath_2016.pdf
Size:
370.64 KB
Format:
Adobe Portable Document Format