Use this link to cite:
http://hdl.handle.net/2183/26633 Construcción izada: condicionantes estructurales del sistema REVERSTOP
Loading...
Identifiers
Publication date
Advisors
Other responsabilities
Universidade da Coruña.Departamento de Construcións e Estruturas Arquitectónicas, Civís e Aeronáuticas
Journal Title
Bibliographic citation
Pérez-Valcárcel, Juan; Muñoz-Vidal, Manuel; Hermo, Víctor (2020). Construcción izada: Condicionantes estructurales del sistema REVERSTOP. Informes de la Construcción, 72(559): e355. https://doi.org/10.3989/ic.72993
Type of academic work
Academic degree
Abstract
[Resumen] Un gran problema para la construcción de edificios es la construcción en altura, lo que supone un riesgo para los trabajadores y un
mayor costo. El sistema REVERSTOP permite la construcción a nivel del suelo y el posterior izado de cada planta. El nivel superior
es el primero en construirse en la planta baja. Este nivel se eleva a través de gatos hidráulicos y se construye un nuevo nivel debajo de
él. Las fases posteriores permiten construir todo el edificio, siempre desde el nivel del suelo. En este artículo se analizan los aspectos
estructurales del sistema. En el caso analizado, la estructura del edificio se compone de perfiles de aluminio que forman las paredes
resistentes, los forjados y la cubierta, con el mismo elemento. Se aportan los cálculos que respaldan la efectividad de la solución y los
resultados experimentales obtenidos en las pruebas realizadas dentro de un proyecto de investigación.
[Abstract] A big problem for the construction of buildings is the construction in height, what supposes a risk for the workers and a greater cost. The patented REVERSTOP system allows the construction at ground level and the subsequent lifting of each plant. The upper level is the first to be built on the ground floor. This level is raised through hydraulic jacks and a new level is built under it. The subsequent phases allow building the entire building, always from the ground level. In this article we analyze the structural aspects of the system. In the case analyzed, the structure of the building consists of aluminum profiles that form the resistant walls, the floors and the roof, with the same element. The calculations that support the effectiveness of the solution and the experimental results obtained in the tests carried out within a research project are provided.
[Abstract] A big problem for the construction of buildings is the construction in height, what supposes a risk for the workers and a greater cost. The patented REVERSTOP system allows the construction at ground level and the subsequent lifting of each plant. The upper level is the first to be built on the ground floor. This level is raised through hydraulic jacks and a new level is built under it. The subsequent phases allow building the entire building, always from the ground level. In this article we analyze the structural aspects of the system. In the case analyzed, the structure of the building consists of aluminum profiles that form the resistant walls, the floors and the roof, with the same element. The calculations that support the effectiveness of the solution and the experimental results obtained in the tests carried out within a research project are provided.
Description
Editor version
Rights
Reconocimiento 4.0 Internacional (CC BY 4.0)