Seismic Behaviour of Non-Prequalified Connections of Reduced Section Beams with Composite Columns

UDC.coleccionInvestigación
UDC.departamentoConstrucións e Estruturas Arquitectónicas, Civís e Aeronáuticas
UDC.endPage57
UDC.grupoInvMecánica de Estruturas (ME)
UDC.institutoCentroCITEEC - Centro de Innovación Tecnolóxica en Edificación e Enxeñaría Civil
UDC.journalTitleWIT Transactions on The Built Environment
UDC.startPage47
UDC.volume217
dc.contributor.authorPillajo, Hugo
dc.contributor.authorRomera, Luis
dc.contributor.authorFontán, Arturo
dc.contributor.authorGutiérrez, Ruth
dc.date.accessioned2026-10-30T19:10:33Z
dc.date.available2026-10-30T19:10:33Z
dc.date.issued2025
dc.description.abstract[Abstract] Reduced beam section (RBS) connection is one of the pre-qualified systems used to ensure the formation of plastic hinges in earthquake-resistant frames. In the case of constructive systems used in buildings in Ecuador, it is common to use composite columns formed by two longitudinally welded steel U-sections filled with concrete and rigidly connected to steel I-beams using welding of webs and flanges. In order to ensure the formation of plastic hinges on the beam flanges at a safe distance from the column, the flange’s cross-sections are reduced by symmetrical circular cut-outs. This type of rigid connections does not form part of the pre-qualified joints, in which steel columns with double Tsections are connected with RBS I-beams so it is necessary to carry out experimental and numerical studies to ensure its ductility due to the high seismicity in the areas in which they are used. In this work we study experimentally and numerically one of the most common designs for beam–column connections used in Ecuador. The design has been calculated numerically against cyclic loads and tested experimentally at the Housing Research Centre of the National Polytechnic School in Quito, following the specifications of the American codes used in Ecuador. The numerical results obtained show a good correlation with the experimental tests in the initial load cycles, but for medium loads a shear fracture develops in the welds of continuity plates and the ductility requirements of the regulations are not fulfilled. Therefore, new designs are proposed in order to improve the seismic response of the connections.
dc.identifier.citationPillajo, H., Romera, L., Fontán, A., & Gutiérrez, R. (2025). Seismic Behaviour of Non-Prequalified Connections of Reduced Section Beams with Composite Columns. WIT Transactions on The Built Environment, 217, 47–57. https://doi.org/10.2495/ERES250051
dc.identifier.doi10.2495/ERES250051
dc.identifier.urihttps://hdl.handle.net/2183/50054
dc.language.isoeng
dc.publisherWIT Press
dc.relation.urihttps://doi.org/10.2495/ERES250051
dc.rights.accessRightsopen access
dc.subjectSeismic design; Ductility
dc.subjectReduced beam sections
dc.subjectBeam–column connections
dc.titleSeismic Behaviour of Non-Prequalified Connections of Reduced Section Beams with Composite Columns
dc.typejournal article
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublication57baab9f-d6c3-4a94-a5d6-c20ed1ca0014
relation.isAuthorOfPublication7be7ef79-992b-446d-b560-4823e993eb62
relation.isAuthorOfPublicationdda7ff2e-c2f7-43f0-bb77-a89e655bc4de
relation.isAuthorOfPublication.latestForDiscovery57baab9f-d6c3-4a94-a5d6-c20ed1ca0014

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
RomeraL_2025_SeismicBehaviour_WTotBE-217_47-57.pdf
Size:
816.95 KB
Format:
Adobe Portable Document Format