Use this link to cite:
http://hdl.handle.net/2183/30013 Modeling the Natural Gas Knocking Behaviour Using Gas-Phase Infrared Spectra and Multivariate Calibration
Loading...
Identifiers
Publication date
Authors
Ponte, Santiago
Vázquez, Cristina
Ferreiro, Borja
Cobas, Carlos
Pérez, Andrés
Rey, María
Vales Fernández, Carlos
Pellitero, José
Santracruz, Blanca
Advisors
Other responsabilities
Journal Title
Bibliographic citation
Ponte, S., Andrade, J.M., Vázquez, C., Ferreiro, B., Cobas, C., Pérez, A., Rey, M., Vales, C., Pellitero, J., Santacruz, B., Muniategui, S., López-Mahía, P., Shu, B., Bettin, H., Klaus, D., Anders, B., Betz, M., Kühne, U., Meier, C., Eilts, P., 2021. Modeling the natural gas knocking behaviour using gas-phase infrared spectra and multivariate calibration. Journal of Natural Gas Science and Engineering 90, 103944. https://doi.org/10.1016/j.jngse.2021.103944
Type of academic work
Academic degree
Abstract
[Abstract] To assess the knocking properties of natural gas (NG) when it is used as fuel for vehicles is vital to optimize the design and functioning of their motors. Analytical efforts in this field are needed as the engines used to define it empirically are not available anymore, and existent mathematical algorithms yield different accuracy. The hybridization of gas-phase infrared spectrometry and partial least squares multivariate regression is presented first time to address the determination of the methane number (MN) of NG samples. It circumvents the need for the previous knowledge of the NG composition required to apply dedicated equations. The use of true NG samples to develop the models is also quite new in the field. Proof-of-concept studies were made with synthetic spectra and, then, a collection of liquefied NG samples for which MN values were computed by the National Physics Laboratory algorithm (NPL) from their sample composition were used to develop operative models. Additional validation was made with a collection of synthetic standard mixtures prepared for two European projects (EMRP LNG II and EMPIR LNG III) whose service methane numbers (SMN) were measured with an engine. The FTIR-PLS approach yielded statistically unbiased predictions with average standard errors around 0.4% MN when compared to the NPL-MN and SMN values, and standard deviations of the means ca. 1% MN. The approach is fast, cost effective as it involves standard instrumentation, and can be considered compliant with the green chemistry principles.
Description
Financiado para publicación en acceso aberto: Universidade da Coruña/CISUG
Editor version
Rights
Atribución-NoComercial-SinDerivadas 4.0 Internacional