dc.contributor.authorPrieto-Blanco, M. C.
dc.contributor.authorJornet-Martínez, Neus
dc.contributor.authorVerdú-Andrés, Jorge
dc.contributor.authorMolíns-Legua, Carmen
dc.contributor.authorCampíns-Falcó, Pilar
dc.date.accessioned2024-10-31T18:59:51Z
dc.date.available2024-10-31T18:59:51Z
dc.date.issued2019-02-01
dc.descriptionThis is an accepted version of the published document.es_ES
dc.description.abstract[Abstract] Two of the reagents involved in the Berthelot's reaction, thymol and nitroprusside, were embedded in a PDMS composite in order to apply this assay to determine ammonium and proline, in wine and beers. Safety, portability, rapidity, cost-effectiveness and simplicity of the assay were improved. For the proline determination, a modified Berthelot's reaction, which included a ring cleavage of proline, was optimized. The accuracy of the assay was tested. The limits of detection for ammonium was 0.12 µg mL−1 and for proline was in the range from 0.7 to 4.1 µg mL−1, depending on the kind of wine (white, red, or sweet), for beer the LOD was 6 µg mL−1. The precision achieved was slower than 10%. The accuracy of the assay was tested by means of a confirmatory validation study. Good results were obtained for real samples.es_ES
dc.description.sponsorshipThe authors are grateful to the Spanish Ministerio de Economia y Competitividad (EU-FEDER/MINECO-AEI-Gobierno de España (CTQ2017-90082-P), Generalitat Valenciana (PROMETEO program 2012/045 and 2016/109), and the Program of Consolidation and Structuring of Units of Competitive Investigation of the University System of Galicia potentially co-financed by ERDF in the frame of the operative Program of Galicia (Xunta de Galicia, reference: ED431C 2017/28). MCP expresses their gratitude to the PROMETEO program for a grant and a research stayes_ES
dc.description.sponsorshipGeneralitat Valenciana; 2012/045es_ES
dc.description.sponsorshipGeneralitat Valenciana; 2016/109es_ES
dc.description.sponsorshipXunta de Galicia; ED431C 2017/28es_ES
dc.identifier.citationPrieto-Blanco, M. C., Jornet-Martinez, N., Verdú-Andrés, J., Molíns-Legua, C., & Campíns-Falcó, P. (2019). Quantifying both ammonium and proline in wines and beer by using a PDMS composite for sensoring. Talanta, 198, 371–376. https://doi.org/10.1016/j.talanta.2019.02.001es_ES
dc.identifier.doi10.1016/j.talanta.2019.02.001
dc.identifier.issn0039-9140
dc.identifier.urihttp://hdl.handle.net/2183/39917
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/CTQ2017-90082-P/ES/MICROEXTRACION EN FASE SOLIDA EN TUBO ACOPLADA EN LINEA A NANOCROMATOGRAFIA LIQUIDA: NUEVAS OPORTUNIDADES PARA %2F DESDE LA NANOESCALA Y LA CROMATOGRAFIA LIQUIDA/es_ES
dc.relation.urihttps://doi.org/10.1016/j.talanta.2019.02.001es_ES
dc.rightsAtribución-NoComercial-SinDerivadas 4.0 Internacionales_ES
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectColorimetric sensores_ES
dc.subjectPDMS compositees_ES
dc.subjectProlinees_ES
dc.subjectAmmonium iones_ES
dc.subjectWineses_ES
dc.subjectDouble solid devicees_ES
dc.titleQuantifying Both Ammonium and Proline in Wines and Beer by Using a PDMS Composite for Sensoringes_ES
dc.typejournal articlees_ES
dspace.entity.typePublication
relation.isAuthorOfPublication6d8a92c4-dd21-4f52-b490-64411e0f0984
relation.isAuthorOfPublication.latestForDiscovery6d8a92c4-dd21-4f52-b490-64411e0f0984

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
PrietoBlanco_MC_2019_Quantifying_ammonium_proline_wines_beer.pdf
Size:
495.1 KB
Format:
Adobe Portable Document Format
Description: