Multicenter evaluation of rapid BACpro® II for the accurate identification of microorganisms directly from blood cultures using MALDI-TOF MS

UDC.coleccionInvestigaciónes_ES
UDC.departamentoFisioterapia, Medicina e Ciencias Biomédicases_ES
UDC.grupoInvInvestigación en Microbiología (INIBIC)es_ES
UDC.institutoCentroINIBIC - Instituto de Investigacións Biomédicas de A Coruñaes_ES
UDC.issue12es_ES
UDC.journalTitleDiagnosticses_ES
UDC.startPage2251es_ES
UDC.volume11es_ES
dc.contributor.authorOviaño, Marina
dc.contributor.authorIngebretsen, André
dc.contributor.authorSteffensen, Anne K.
dc.contributor.authorCroxatto, Antony
dc.contributor.authorProd’hom, Guy
dc.contributor.authorQuiroga, Lidia
dc.contributor.authorBou, Germán
dc.contributor.authorGreub, Gilbert
dc.contributor.authorRodríguez-Temporal, David
dc.contributor.authorRodríguez-Sánchez, Belén
dc.date.accessioned2025-02-13T10:55:35Z
dc.date.available2025-02-13T10:55:35Z
dc.date.issued2021-12-01
dc.description.abstract[Abstract] The identification of microorganisms directly from blood cultures using MALDI-TOF MS has been shown to be the most impacting application of this methodology. In this study, a novel commercial method was evaluated in four clinical microbiology laboratories. Positive blood culture samples (n = 801) were processed using a rapid BACpro® II kit and then compared with the routine gold standard. A subset of monomicrobial BCs (n = 560) were analyzed in parallel with a Sepsityper® Kit (Bruker Daltonics, Bremen, Germany) and compared with the rapid BACpro® II kit. In addition, this kit was also compared with two different in-house methods. Overall, 80.0% of the monomicrobial isolates (609/761; 95% CI 71.5-88.5) were correctly identified by the rapid BACpro® II kit at the species level (92.3% of the Gram negative and 72.4% of the Gram positive bacteria). The comparison with the Sepsityper® Kit showed that the rapid BACpro® II kit generated higher rates of correct species-level identification for all categories (p > 0.0001), except for yeasts identified with score values > 1.7. It also proved superior to the ammonium chloride method (p > 0.0001), but the differential centrifugation method allowed for higher rates of correct identification for Gram negative bacteria (p > 0.1). The percentage of accurate species-level identification of Gram positive bacteria was particularly noteworthy in comparison with other commercial and in-house methods.es_ES
dc.identifier.citationOviaño M, Ingebretsen A, Steffensen AK, Croxatto A, Prod'hom G, Quiroga L, Bou G, Greub G, Rodríguez-Temporal D, Rodríguez-Sánchez B. Multicenter evaluation of rapid BACpro® II for the accurate identification of microorganisms directly from blood cultures using MALDI-TOF MS. Diagnostics (Basel). 2021 Dec 1;11(12):2251.es_ES
dc.identifier.doi10.3390/diagnostics11122251
dc.identifier.issn2075-4418
dc.identifier.urihttp://hdl.handle.net/2183/41173
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.relation.urihttps://doi.org/10.3390/diagnostics11122251es_ES
dc.rightsCreative Commons Attribution 4.0 International LIcense (CC-BY 4.0)es_ES
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.subjectMALDI-TOFes_ES
dc.subjectBlood culturees_ES
dc.subjectMass spectrometryes_ES
dc.subjectRapid BACpro® II kites_ES
dc.subjectRapid identificationes_ES
dc.titleMulticenter evaluation of rapid BACpro® II for the accurate identification of microorganisms directly from blood cultures using MALDI-TOF MSes_ES
dc.typejournal articlees_ES
dspace.entity.typePublication
relation.isAuthorOfPublication909e08d1-6ed1-4b99-9e9e-c64eb72e7dea
relation.isAuthorOfPublication.latestForDiscovery909e08d1-6ed1-4b99-9e9e-c64eb72e7dea

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Oviano_Multicenter_2021.pdf
Size:
1016.21 KB
Format:
Adobe Portable Document Format
Description:
Loading...
Thumbnail Image
Name:
Oviano_Multicenter_2021_Supple.pdf
Size:
121.51 KB
Format:
Adobe Portable Document Format
Description:
Supplementary material