Resilient Design in Extreme Climates: 5-Steps Overheating Assessment Method for Naturally Ventilated Buildings

UDC.coleccionInvestigaciónes_ES
UDC.departamentoProxectos Arquitectónicos, Urbanismo e Composiciónes_ES
UDC.institutoCentroCITEEC - Centro de Innovación Tecnolóxica en Edificación e Enxeñaría Civiles_ES
dc.contributor.authorZepeda Rivas, Daniel
dc.contributor.authorRodríguez-Álvarez, Jorge
dc.contributor.authorGarcía-Chávez, José Roberto
dc.date.accessioned2025-01-20T12:06:16Z
dc.date.available2025-01-20T12:06:16Z
dc.date.issued2022-04-19
dc.descriptionThis is an Accepted Manuscript of a book chapter published by Routledge/CRC Press in Routledge Handbook of Resilient Thermal Comfort on, 19 April 2022, available online: http://www.routledge.com/9781003244929es_ES
dc.description.abstract[Abstract] Owing to human-induced global warming, overheating has become a major factor in energy consumption, the main source of discomfort and a health risk for the vulnerable population. It has been widely reported how human mortality rises during heatwaves. Paradoxically, the inhabitants of air-conditioned buildings are often exposed to artificially created low temperatures increasing the thermal shock with respect to the outdoor conditions. As a result of the popularization of mechanical systems, energy consumption peaks during hot periods. A vicious loop emerges as CO2 and greenhouse gas emissions generated to mitigate the consequences of global warming will further contribute to exacerbate it. Despite the magnitude of the problem, there is no broadly accepted single method for measuring overheating in naturally ventilated buildings. Most of the published methods rely on a simple count of hours above a theoretical comfort limit, regardless of the intensity and temporal extent of the overheating periods. This deterministic approach makes difficult the introduction of passive strategies as it falls short of accounting for adaptive measures. This paper proposes a novel five-step overheating assessment method (5-SOAM) in naturally ventilated buildings. The study aims to provide a more flexible framework to assess the actual suitability of indoor spaces for human habitation through an analysis of the likelihood of overheating frequency and intensity. The proposed method applies adaptive comfort theories and it has been conceived to account for acclimatization in Tropical and Subtropical regions. It is based on the tabulation of overheating occurrence in five bands, reflecting the thermal difference from the upper comfort threshold (i.e., hours above 0.1°K, 1°K, 2°K, 3°K, and 4°K). The output of the method provides a sensitive index that determines the scale of overheating risk in buildings.es_ES
dc.identifier.citationZepeda-Rivas, D. Rodríguez-Álvarez, J., & García-Chávez, J.R. (2022). Resilient Design in Extreme Climates: 5-Steps Overheating Assessment Method for Naturally Ventilated Buildings. En F. Nicol, H. Bahadur Rijal, & S. Roaf, Routledge Handbook of Resilient Thermal Comfort (Part II. Chapter 5). Routledge/Taylor & Francis Group.es_ES
dc.identifier.isbn9781003244929
dc.identifier.urihttp://hdl.handle.net/2183/40777
dc.language.isoenges_ES
dc.publisherRoutledge/Taylor & Francis Groupes_ES
dc.relation.urihttps://doi.org/10.4324/9781003244929es_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Españaes_ES
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subjectBuilt environmentes_ES
dc.titleResilient Design in Extreme Climates: 5-Steps Overheating Assessment Method for Naturally Ventilated Buildingses_ES
dc.typebook partes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication25f9ef49-2b6a-4d4c-800e-6e58d7bd2763
relation.isAuthorOfPublication.latestForDiscovery25f9ef49-2b6a-4d4c-800e-6e58d7bd2763

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
RodriguezAlvarez_Jorge_2022_Resilient_Design_Extreme_Climates.pdf
Size:
1.88 MB
Format:
Adobe Portable Document Format
Description: