The QardioArm Blood Pressure App for Self-Measurement in an Obese Population: Validation Study Using the European Society of Hypertension International Protocol Revision 2010
| UDC.coleccion | Investigación | es_ES |
| UDC.departamento | Ciencias da Saúde | es_ES |
| UDC.grupoInv | Grupo de Investigación Saúde e Podoloxía (GISAP) | es_ES |
| UDC.issue | 10 | es_ES |
| UDC.journalTitle | JMIR mHealth and uHealth | es_ES |
| UDC.startPage | e11632 | es_ES |
| UDC.volume | 6 | es_ES |
| dc.contributor.author | López-López, Daniel | |
| dc.contributor.author | Mazoteras-Pardo, Victoria | |
| dc.contributor.author | Becerro-de-Bengoa-Vallejo, Ricardo | |
| dc.contributor.author | Losa Iglesias, Marta Elena | |
| dc.contributor.author | Palomo-López, Patricia | |
| dc.contributor.author | Rodríguez Sanz, David | |
| dc.contributor.author | Calvo-Lobo, César | |
| dc.date.accessioned | 2022-03-23T13:48:50Z | |
| dc.date.available | 2022-03-23T13:48:50Z | |
| dc.date.issued | 2018-10 | |
| dc.description.abstract | [Abstract] Background: Obesity and high blood pressure (HBP) pose high cardiovascular risks, and they are frequent causes of cardiovascular disease. Objective: The aim of this study was to validate the mobile app QardioArm for high blood pressure monitoring in obese subjects (body mass index ≥30 kg/m2) according to guidelines in the European Society of Hypertension-International Protocol 2 (ESH-IP2). Methods: We recruited 33 obese subjects and measured their blood pressure using QardioArm (test device) and Omron M3 Intellisense (Omron Healthcare, Kyoto, Japan; standard device). We compared systolic blood pressure (SBP), diastolic blood pressure (DBP), and heart rate (HR) according to the ESH-IP2. Results: A total of 95 of 99 differences for SBP and 91 of 99 for DBP displayed absolute differences within 10 mm Hg. A total of 98 of 99 differences for SBP and 98 of 99 for DBP exhibited absolute differences within 15 mm Hg. This result satisfied requirements for part 1 of the ESH-IP2. A total of 27 out of 33 individuals for SBP and 30 out of 33 individuals for DBP had a minimum of 2 of 3 comparisons within 5 mm Hg difference. None of the subjects had 3 differences outside 5 mm Hg for SBP and DBP, satisfying part 2 of the ESH-IP2. For HR measurements, a total of 90 of 99 differences had absolute differences within 3 beats per minute (bpm), and a total of 94 or 99 differences had absolute differences within 5 bpm. A total of 98 of 99 differences had absolute differences within 8 bpm. Therefore, the test device satisfied part 1 of ESH-IP2 criteria for HR. For part 2 of ESH-IP2, 31 of 33 individuals had a minimum of 2 of 3 comparisons within 3 bpm difference for HR. Only 1 of 33 subjects had 3 differences outside 3 bpm. Conclusions: To the best of our knowledge, this was the first study to show that an app that measures blood pressure and HR meets the requirements of the ESH-IP2 in an obese population. We believe the ESH-IP2 should publish explicit criteria for validation of blood pressure devices in specific populations. | es_ES |
| dc.identifier.citation | Mazoteras-Pardo V, Becerro-De-Bengoa-Vallejo R, Losa-Iglesias M, López-López D, Palomo-López P, Rodríguez-Sanz D, Calvo-Lobo C The QardioArm Blood Pressure App for Self-Measurement in an Obese Population: Validation Study Using the European Society of Hypertension International Protocol Revision 2010 JMIR Mhealth Uhealth 2018;6(10):e11632 URL: https://mhealth.jmir.org/2018/10/e11632 DOI: 10.2196/11632 | es_ES |
| dc.identifier.uri | http://hdl.handle.net/2183/30189 | |
| dc.language.iso | eng | es_ES |
| dc.publisher | JMIR | es_ES |
| dc.relation.uri | doi:10.2196/11632 | es_ES |
| dc.rights | Atribución 3.0 España | es_ES |
| dc.rights.accessRights | open access | es_ES |
| dc.rights.uri | http://creativecommons.org/licenses/by/3.0/es/ | * |
| dc.subject | Obesity | es_ES |
| dc.subject | Obesidad | es_ES |
| dc.subject | Blood pressure determination | es_ES |
| dc.subject | Determinación de la presión arterial | es_ES |
| dc.title | The QardioArm Blood Pressure App for Self-Measurement in an Obese Population: Validation Study Using the European Society of Hypertension International Protocol Revision 2010 | es_ES |
| dc.type | journal article | es_ES |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 80e827fb-79b5-45af-9756-581db1fa7b73 | |
| relation.isAuthorOfPublication.latestForDiscovery | 80e827fb-79b5-45af-9756-581db1fa7b73 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- LopezLopez_Daniel_2018_Qardioarm_blood_App.pdf
- Size:
- 482.4 KB
- Format:
- Adobe Portable Document Format
- Description: