Design and Optimization of an Electrochemical Sensor Based on Carbon Nanotubes for the Reliable Voltammetric Detection of Serotonin in Complex Biological Fluids

UDC.coleccionInvestigación
UDC.departamentoQuímica
UDC.grupoInvReactividade Química e Fotorreactividade (REACT!)
UDC.grupoInvNanochemistry and Self-Assembly for Biological Sciences (NANOSELF4BIO)
UDC.institutoCentroCICA - Centro Interdisciplinar de Química e Bioloxía
UDC.journalTitleCarbon
UDC.startPage119550
UDC.volume229
dc.contributor.authorMisia, Giuseppe
dc.contributor.authorEvangelisti, Claudio
dc.contributor.authorMerino, Juan P.
dc.contributor.authorPitzalis, Emanuela
dc.contributor.authorAbelairas, Adrián M.
dc.contributor.authorMosquera Mosquera, Jesús
dc.contributor.authorCriado, Alejandro
dc.contributor.authorPrato, Maurizio
dc.contributor.authorSilvestri, Alessandro
dc.date.accessioned2026-10-09T11:29:16Z
dc.date.available2026-10-09T11:29:16Z
dc.date.issued2024-08-27
dc.description.abstract[Abstract] Serotonin concentration in peripherical biological fluids is correlated with the insurgence of several pathologies and represents valuable information on the human physical and mental state of health. Rapid, portable, and reliable electrochemical sensors can mine this useful information in real-time and in situ. However, the main challenge that hampers their implementation is the poor operational stability in biological fluids rich in bio-macromolecules, which can induce the fouling of the electrode altering or invalidating the analytical performance of the sensor. Herein, we propose the design of a reliable and robust voltammetric sensor for detecting serotonin in plasma. The sensor is based on multiwall carbon nanotubes modified with ligand-free gold nanoparticles obtained by metal vapor synthesis, which can efficiently catalyze the oxidation of serotonin. A thin layer of molecular imprinted polymer is added to provide selectivity and antifouling properties to the sensor. By applying a design of the experiment, to optimize the experimental condition of the differential pulsed voltammetry, and adsorptive stripping to selectively pre-accumulate serotonin in the artificial receptor, we achieved serotonin detection in plasma with sensitivity (6.7 μA μmol L−1 cm−2) and limits of detection (1.0 μmol L−1) comparable to those registered in phosphate buffer solution.
dc.description.sponsorshipA.C. and J.M. acknowledge financial support by MCIN/AEI/ 10.13039/501100011033 and “ESF: Investing in Your Future” (Grant RYC2020-030183-I to A.C., RYC2019-027842-I to J.M., PID2021- 127002NA-I00 to A.C., PID2020-117885 GA-I00 to J.M.).
dc.identifier.citationMisia, G., Evangelisti, C., Merino, J.P., Pitzalis, E., Abelairas, A.M., Mosquera, J., Criado, A., Prato, M., Silvestri, A., 2024. Design and optimization of an electrochemical sensor based on carbon nanotubes for the reliable voltammetric detection of serotonin in complex biological fluids. Carbon 229, 119550. https://doi.org/10.1016/j.carbon.2024.119550
dc.identifier.doi10.1016/j.carbon.2024.119550
dc.identifier.issn0008-6223
dc.identifier.urihttps://hdl.handle.net/2183/49667
dc.language.isoeng
dc.publisherElsevier
dc.relation.projectIDInfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RYC2020-030183-I/ES/
dc.relation.projectIDInfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RYC2019-027842-I/ES/
dc.relation.projectIDInfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/AEI/PID2021-127002NA-I00/SINTESIS DE NANOTIRAS DE GRAFENO BASADAS EN PEPTIDOS PARA BIOAPLICACIONES/
dc.relation.projectIDInfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/AEI/PID2020-117885GA-I00/POLIMEROS SUPRAMOLECULARES COMO MOLDES PARA LA SINTESIS DE NANOPARTICULAS PLASMONICAS QUIRALES/
dc.relation.urihttps://doi.org/10.1016/j.carbon.2024.119550
dc.rightsAttribution 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectSerotonin
dc.subjectElectrochemical sensor
dc.subjectDifferential pulsed voltammetry (DPV)
dc.subjectCarbon nanotubes (CNT)
dc.subjectGold nanoparticles (Au NPs)
dc.subjectMetal vapor synthesis (MVS)
dc.subjectMolecular imprinted polymers (MIP)
dc.subjectDesign of experiment (DoE)
dc.titleDesign and Optimization of an Electrochemical Sensor Based on Carbon Nanotubes for the Reliable Voltammetric Detection of Serotonin in Complex Biological Fluids
dc.typejournal article
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublicationd375c056-bd6f-46df-93b5-07e8cf84500a
relation.isAuthorOfPublication0601ca03-b0d0-4450-be29-4cda2333df5e
relation.isAuthorOfPublication.latestForDiscoveryd375c056-bd6f-46df-93b5-07e8cf84500a

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Mosquera_Jesus_2024_Design_optimization_electrochemical_sensor.pdf
Size:
5.97 MB
Format:
Adobe Portable Document Format