Testing a Novel Biotechnological Passive Sampler for Monitoring Atmospheric Pah Pollution

UDC.coleccionInvestigaciónes_ES
UDC.departamentoQuímicaes_ES
UDC.grupoInvQuímica Analítica Aplicada (QANAP)es_ES
UDC.institutoCentroCICA - Centro Interdisciplinar de Química e Bioloxíaes_ES
UDC.institutoCentroInstituto Universitario de Medio Ambientees_ES
UDC.journalTitleJournal of Hazardous Materialses_ES
UDC.startPage120949es_ES
UDC.volume381 (5 January 2020)es_ES
dc.contributor.authorAboal, Jesús R.
dc.contributor.authorConcha-Graña, Estefanía
dc.contributor.authorDe Nicola, Flavia
dc.contributor.authorMuniategui, Soledad
dc.contributor.authorLópez-Mahía, P.
dc.contributor.authorGiordano, Simonetta
dc.contributor.authorCapozzi, F.
dc.contributor.authorDi Palma, Anna
dc.contributor.authorReski, Ralf
dc.contributor.authorZechmeister, Harald
dc.contributor.authorMartínez-Abaigar, Javier
dc.contributor.authorFernández, J. Ángel
dc.date.accessioned2025-01-30T15:58:35Z
dc.date.available2025-01-30T15:58:35Z
dc.date.issued2020-01-05
dc.descriptionThis is an accepted version of the published document.es_ES
dc.description.abstract[Abstract] In this study we evaluated a new type of passive air sampler, the “mossphere” device, filled with a Sphagnum palustre clone. For this purpose, we compared the atmospheric levels of polyaromatic hydrocarbons (PAHs) collected using this device and those collected in conventional bulk deposition and particulate matter (PM10) samplers. All three types of samplers were exposed at 10 sites affected by different levels of pollution and located in two different climate zones. The bulk deposition/ mossphere comparison yielded a greater number of significant regressions with higher coefficients of determination than the PM10/ mossphere comparison. No significant regressions were observed for 3-ring PAHs in either comparison. The mosspheres explain ca. 50% of the variability of the concentrations of 4-, 5- and 6-ring PAHs and total PAHs detected in PM10 and ca. 70% of the corresponding concentrations detected in the bulk deposition. The use of the Sphagnum clone enables standardization of the set-up, thus making the mossphere device a good sampling tool for monitoring 4-, 5- and 6-ring and total PAHs, especially those associated with bulk deposition. The findings indicate the potential usefulness of this innovative technology for mapping PAH levels.es_ES
dc.description.sponsorshipThis study received financial support from FP7- ENV.2011.3.1.9e1 MOSSclone project of the European Union in the Seventh Framework Program (FP7) for Research and Technological Development. This article is based on research work partly supported by FESR Campania 2014 – 2020 (GRISIS project CUP: B63D180002800079)es_ES
dc.description.sponsorshipItalia. Regione Campania; B63D180002800079es_ES
dc.identifier.citationAboal, J.R., Concha-Graña, E., De Nicola, F., Muniategui-Lorenzo, S., López-Mahía, P., Giordano, S., Capozzi, F., Di Palma, A., Reski, R., Zechmeister, H., Martínez-Abaigar, J., Fernández, J.A., 2020. Testing a novel biotechnological passive sampler for monitoring atmospheric PAH pollution. Journal of Hazardous Materials 381, 120949. https://doi.org/10.1016/j.jhazmat.2019.120949es_ES
dc.identifier.doi10.1016/j.jhazmat.2019.120949
dc.identifier.issn0304-3894
dc.identifier.urihttp://hdl.handle.net/2183/40989
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/FP7/282952es_ES
dc.relation.urihttps://doi.org/10.1016/j.jhazmat.2019.120949es_ES
dc.rightsAtribución-NoComercial-SinDerivadas 4.0 Internacionales_ES
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectMoss bagses_ES
dc.subjectActive monitoringes_ES
dc.subjectPolycyclic aromatic hydrocarbonses_ES
dc.titleTesting a Novel Biotechnological Passive Sampler for Monitoring Atmospheric Pah Pollutiones_ES
dc.typejournal articlees_ES
dspace.entity.typePublication
relation.isAuthorOfPublication2a55bdc6-d9e2-4220-98b5-c0d438e6d54b
relation.isAuthorOfPublicationfdd1eb2d-3ea9-4ea4-b3ed-1357931187bc
relation.isAuthorOfPublicationb50bd2e9-cf34-4382-b8e1-3419b9503214
relation.isAuthorOfPublication.latestForDiscovery2a55bdc6-d9e2-4220-98b5-c0d438e6d54b

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
LopezMahia_P_2020_Testing_novel_biotechnological_passive_sampler.pdf
Size:
945.85 KB
Format:
Adobe Portable Document Format
Description:
Loading...
Thumbnail Image
Name:
LopezMahia_P_2020_Testing_novel_biotechnological_passive_sampler_Supplementary.pdf
Size:
1.13 MB
Format:
Adobe Portable Document Format
Description: