Use of the cobas 4800 system for the rapid detection of toxigenic Clostridium difficile and methicillin-resistant Staphylococcus aureus

UDC.coleccionInvestigación
UDC.departamentoFisioterapia, Medicina e Ciencias Biomédicas
UDC.endPage52
UDC.grupoInvInvestigación en Microbiología (INIBIC)
UDC.institutoCentroINIBIC - Instituto de Investigacións Biomédicas de A Coruña
UDC.journalTitleJournal of Microbiological Methods
UDC.startPage50
UDC.volume120
dc.contributor.authorMoure, Raquel
dc.contributor.authorCañizares, Angelina
dc.contributor.authorMuíño, María
dc.contributor.authorLobato, Margarita
dc.contributor.authorViña Fernández, Anabel María
dc.contributor.authorRodríguez, María E.
dc.contributor.authorGude, María José
dc.contributor.authorTomás, María
dc.contributor.authorBou, Germán
dc.date.accessioned2026-07-09T08:01:16Z
dc.date.available2026-07-09T08:01:16Z
dc.date.issued2015-11-29
dc.description.abstract[Abstract] The new cobas® Cdiff and cobas® MRSA/SA tests were compared with conventional methods for the rapid detection of toxigenic Clostridium difficile and methicillin-resistant Staphylococcus aureus. The final concordance between cobas Cdiff Test and GDH/toxin gene screening was 97.62% and between cobas MRSA/SA Test and chromogenic culture, 91.30%, respectively.
dc.identifier.citationMoure R, Cañizares Á, Muíño M, Lobato M, Fernández A, Rodríguez M, Gude MJ, Tomás M, Bou G. Use of the cobas 4800 system for the rapid detection of toxigenic Clostridium difficile and methicillin-resistant Staphylococcus aureus. J Microbiol Methods. 2016 Jan;120:50-2.
dc.identifier.doi10.1016/J.MIMET.2015.11.014
dc.identifier.issn1872-8359
dc.identifier.urihttps://hdl.handle.net/2183/48835
dc.language.isoeng
dc.publisherElsevier
dc.relation.urihttps://doi.org/10.1016/J.MIMET.2015.11.014
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectClostridium difficile
dc.subjectCobas 4800
dc.subjectMRSA
dc.subjectReal-time PCR
dc.titleUse of the cobas 4800 system for the rapid detection of toxigenic Clostridium difficile and methicillin-resistant Staphylococcus aureus
dc.typejournal article
dc.type.hasVersionAM
dspace.entity.typePublication
relation.isAuthorOfPublication909e08d1-6ed1-4b99-9e9e-c64eb72e7dea
relation.isAuthorOfPublication.latestForDiscovery909e08d1-6ed1-4b99-9e9e-c64eb72e7dea

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Moure_Usecobas_2016.pdf
Size:
227.93 KB
Format:
Adobe Portable Document Format