Full scale testing of timber-concrete composite floors in an overhanging configuration

UDC.coleccionInvestigaciónes_ES
UDC.departamentoConstrucións e Estruturas Arquitectónicas, Civís e Aeronáuticases_ES
UDC.grupoInvGrupo de Estruturas Arquitectónicas (GEA)es_ES
UDC.issue291es_ES
UDC.journalTitleEngineering Structureses_ES
UDC.startPage116460es_ES
dc.contributor.authorEstévez-Cimadevila, Javier
dc.contributor.authorSuárez-Riestra, Félix
dc.contributor.authorMartín-Gutiérrez, Emilio
dc.contributor.authorOtero-Chans, Dolores
dc.date.accessioned2023-10-30T10:04:42Z
dc.date.available2023-10-30T10:04:42Z
dc.date.issued2023-06-19
dc.descriptionFinanciado para a publicación en acceso aberto: Universidade da Coruña/CISUGes_ES
dc.description.abstract[Abstract] The behavior of timber-concrete composite floors in an overhanging configuration has been analysed. The floor consisted of a prefabricated T-shape piece formed by a glulam flange glued to a plywood rib and connected to an upper concrete slab poured in situ. The connection between both materials is achieved by penetrating the concrete into the holes made in the rib. Three-point bending tests were performed with a total of 8 specimens with depth of 25, 30 and 35 cm and overhanging length of 1.50, 1.80 and 2.10 m, respectively. That means a length-to-depth ratio equal to 6 in all cases. The experimental results showed that the lowest ultimate load value obtained was 8.03 and 5.55 times higher than the estimated service load for a building with residential use (5 kN/m²) and public use (9 kN/m²), respectively. Two types of failure were observed after a marked cracking process in the concrete as the ultimate load value was approached: tensile failure affecting the plywood rib and shear failure at the glulam flange-plywood rib connection. The maximum deflection for the total load was between 1/358 and 1/523 of the overhanging span for the estimated loads for a residential use building (5 kN/m²), and between 1/266 and 1/390 for public use buildings (9 kN/m²). Regarding to vibrations, floors in an overhanging configuration with a length-to-depth ratio equal to 6 and a simply supported portion equal to four times the length of the overhanging portion, with total loads up to 9.0 kN/ m², both in multi-storey buildings for residential and office use, present a high comfort level. Consequently, the proposed timber-concrete composite (TCC) overhanging floor solution has demonstrated high stiffness and strength that make it a suitable alternative for the construction of high-performance lightweight floors in multi-storey buildings.es_ES
dc.description.sponsorshipAgencia Estatal de Investigación: 10.13039/501100011033es_ES
dc.identifier.citationEstévez-Cimadevila, J., Suárez-Riestra, F., Martín-Gutiérrez, E., & Otero-Chans, D. (2023). Full scale testing of timber-concrete composite floors in an overhanging configuration. Engineering Structures, 291, 116460. https://doi.org/10.1016/j.engstruct.2023.116460es_ES
dc.identifier.issn0141-0296
dc.identifier.urihttp://hdl.handle.net/2183/33978
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.relation.urihttps://doi.org/10.1016/j.engstruct.2023.116460es_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Españaes_ES
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subjectTimber-concrete compositees_ES
dc.subjectTimber flooring systemses_ES
dc.subjectMixed beamses_ES
dc.subjectCantilever floorses_ES
dc.titleFull scale testing of timber-concrete composite floors in an overhanging configurationes_ES
dc.typejournal articlees_ES
dspace.entity.typePublication
relation.isAuthorOfPublicationfa74955a-a9e7-4738-9489-c65325fc12d1
relation.isAuthorOfPublicationc0f42de2-b428-41dc-a11a-17b55db8c543
relation.isAuthorOfPublication6428189e-b6c0-4c9b-8a94-10c1a49e4e25
relation.isAuthorOfPublicationed6a607c-1d7a-4afc-a340-9cef8f5ef523
relation.isAuthorOfPublication.latestForDiscoveryfa74955a-a9e7-4738-9489-c65325fc12d1

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
EstevezCimadevila_Javier_2023_Full_scale_testing_timber_concrete_ composite_floors.pdf
Size:
15.63 MB
Format:
Adobe Portable Document Format
Description: