On the Vertical Size of Two-Phase Pool Boiling Structures

UDC.coleccionInvestigación
UDC.departamentoEnxeñaría Naval e Industrial
UDC.grupoInvSistemas Térmicos e Transferencia de Calor (SISTER)
UDC.grupoInvLaboratorio de Aplicacións Industriais do Láser (LAIL)
UDC.issue2
UDC.journalTitleInternational Journal of Heat and Mass Transfer
UDC.startPage129733
UDC.volume273
dc.contributor.authorTalão Martins, Iván
dc.contributor.authorFariñas Alvariño, Pablo
dc.contributor.authorCabezas-Gómez, Luben
dc.contributor.authorAmado, José
dc.date.accessioned2026-11-04T15:27:55Z
dc.date.available2026-11-04T15:27:55Z
dc.date.issued2026-10-24
dc.descriptionFinanciado para publicación en acceso aberto: Universidade da Coruña/CISUG
dc.description.abstract[Abstract] In a previous publication, the authors identified that the two-phase boiling structure arising from a boiling surface exhibits periodic behavior over time. This new research constitutes a step forward, as it reports and characterizes the vertical size of the boiling structure. The experimental data used comprehends a boiling curve of saturated HFE-7100 at 100 kPa with a polished copper surface. The comparison between the width signal and the two-phase structure videos revealed that the vertical size of the sub-structures is related to the wavelengths of the function that provides the whole boiling structure. This manuscript shows that larger structures are related to larger wavelengths of the function. This analysis also proves that all wavelengths (bubbles vertical sizes) are present inside the two-phase structure. An outstanding finding of this research is the linear relationship between the position of the structure center when it first appears, y, and the wavelength associated with this structure, λ. This relation is y=0.75λ. The present paper brings forth new insights into the periodic nature of the two-phase boiling structure from a spatial point of view. This approach constitutes an additional and relevant insight on boiling phenomena.
dc.description.sponsorshipThis study was financed, in part, by the São Paulo Research Foundation (FAPESP), Brasil, process Number 2021/14338-0, 2022/15765-1, 2023/02383-6 and 2024/21322-0, and in part by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - Brasil (CAPES) - Finance Code 001. The authors also acknowledge the support received from CNPq (National Council for Scientific and Technological Development), process 305771/2023-0, and the funding for open access charge from Universidade da Coruña/CISUG
dc.description.sponsorshipBrasil. Fundação de Amparo à Pesquisa do Estado de São Paulo; 2021/14338-0
dc.description.sponsorshipBrasil. Fundação de Amparo à Pesquisa do Estado de São Paulo; 2022/15765-1
dc.description.sponsorshipBrasil. Fundação de Amparo à Pesquisa do Estado de São Paulo; 2023/02383-6
dc.description.sponsorshipBrasil. Fundação de Amparo à Pesquisa do Estado de São Paulo; 2024/21322-0
dc.description.sponsorshipBrasil. Conselho Nacional de Desenvolvimento Científico e Tecnológico; 305771/2023-0
dc.identifier.citationI.T. Martins, P.F. Alvariño, L. Cabezas-Gómez, J.M.A. Paz, On the vertical size of two-phase pool boiling structures, International Journal of Heat and Mass Transfer 273 (2027) 129733. https://doi.org/10.1016/j.ijheatmasstransfer.2026.129733.
dc.identifier.doi10.1016/j.ijheatmasstransfer.2026.129733
dc.identifier.issn1879-2189
dc.identifier.urihttps://hdl.handle.net/2183/50118
dc.language.isoeng
dc.publisherElsevier
dc.relation.urihttps://doi.org/10.1016/j.ijheatmasstransfer.2026.129733
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectPool boiling
dc.subjectSpectral analysis
dc.subjectMultiphase flows
dc.subjectBoiling structures
dc.subjectBoiling surface
dc.titleOn the Vertical Size of Two-Phase Pool Boiling Structures
dc.typejournal article
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublication666ee8dc-7d6b-4c82-8fa8-20041445e69c
relation.isAuthorOfPublication88cc1d89-341c-499e-b674-1b50bbd4cb43
relation.isAuthorOfPublication8c23c132-a8b0-420b-a63e-62e1689fb5c1
relation.isAuthorOfPublication.latestForDiscovery666ee8dc-7d6b-4c82-8fa8-20041445e69c

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
TalaoMartins_Ivan_2026_On-the-vertical-size-of-two-phase-pool-boiling-structures.pdf
Size:
3.5 MB
Format:
Adobe Portable Document Format