Influence of Gas Desorption in a Safety Relief Valve Undergoing Cavitation

Thumbnail
Not available until 9999-99-99
Request a copy
View/Open
Lema_Rodriguez_Marcos_2019_Influence_gas_desorption_safety_relief_valve_cavitation.pdf (513.7Kb)
Use this link to cite
http://hdl.handle.net/2183/35283
Collections
  • Investigación (EPEF) [593]
Metadata
Show full item record
Title
Influence of Gas Desorption in a Safety Relief Valve Undergoing Cavitation
Author(s)
Lema, Marcos
Gosset, Anne
López Peña, Fernando
Date
2019-12-27
Citation
LEMA, Marcos, GOSSET, Anne and PEÑA, Fernando López, 2019. Influence of Gas Desorption in a Safety Relief Valve Undergoing Cavitation. International Journal of Fluid Machinery and Systems. Online. December 2019. Vol. 12, no. 4, p. 451–458. DOI 10.5293/IJFMS.2019.12.4.451
Abstract
[Abstract]: In this study, the characterization of the flow through a safety relief valve (SRV) is performed in presence of cavitation and gas desorption. For this purpose, a transparent safety relief valve model is used on an experimental facility in which the flow conditions (mass flow rate, fluid temperature, and pressure upstream and downstream the valve) are accurately monitored. For six different valve openings, the characteristic curves of the valve are measured while flow visualization is performed on the transparent model. The results show that choked flow conditions are reached for the six valve openings used in this study, and with a remarkable repeatability. In order to take into consideration the gas saturation level of the working fluid, the vacuum system used to adjust the pressure downstream the valve is also used for gas desorption by storing the liquid under vacuum conditions, a process known as vacuum degasification. In saturated liquids the evolved gas bubbles modify the flow properties, such as the speed of sound, and this may have an influence in the cavitation inception and the occurrence of choked flow. This study proves that gas saturated water in standard conditions (atmospheric pressure and 293 K) has the same behavior that fully deaerated water, both under the same cavitating conditions. It is thus not necessary to take the saturation level of the liquid into account when in standard conditions.
Keywords
Safety relief valve
Cavitation
Gas desorption
Flow visualization
Vacuum degasification
Choked flow
 
Editor version
http://dx.doi.org/10.5293/IJFMS.2019.12.4.451