Full scale testing of timber-concrete composite floors in an overhanging configuration

Thumbnail
Ver/Abrir
EstevezCimadevila_Javier_2023_Full_scale_testing_timber_concrete_ composite_floors.pdf (15.63Mb)
Use este enlace para citar
http://hdl.handle.net/2183/33978
Atribución-NoComercial-SinDerivadas 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-SinDerivadas 3.0 España
Colecciones
  • Investigacion (ETSAC) [511]
Metadatos
Mostrar el registro completo del ítem
Título
Full scale testing of timber-concrete composite floors in an overhanging configuration
Autor(es)
Estévez-Cimadevila, Javier
Suárez-Riestra, Félix
Martín-Gutiérrez, Emilio
Otero-Chans, Dolores
Fecha
2023-06-19
Cita bibliográfica
Estévez-Cimadevila, J., Suárez-Riestra, F., Martín-Gutiérrez, E., & Otero-Chans, D. (2023). Full scale testing of timber-concrete composite floors in an overhanging configuration. Engineering Structures, 291, 116460. https://doi.org/10.1016/j.engstruct.2023.116460
Resumen
[Abstract] The behavior of timber-concrete composite floors in an overhanging configuration has been analysed. The floor consisted of a prefabricated T-shape piece formed by a glulam flange glued to a plywood rib and connected to an upper concrete slab poured in situ. The connection between both materials is achieved by penetrating the concrete into the holes made in the rib. Three-point bending tests were performed with a total of 8 specimens with depth of 25, 30 and 35 cm and overhanging length of 1.50, 1.80 and 2.10 m, respectively. That means a length-to-depth ratio equal to 6 in all cases. The experimental results showed that the lowest ultimate load value obtained was 8.03 and 5.55 times higher than the estimated service load for a building with residential use (5 kN/m²) and public use (9 kN/m²), respectively. Two types of failure were observed after a marked cracking process in the concrete as the ultimate load value was approached: tensile failure affecting the plywood rib and shear failure at the glulam flange-plywood rib connection. The maximum deflection for the total load was between 1/358 and 1/523 of the overhanging span for the estimated loads for a residential use building (5 kN/m²), and between 1/266 and 1/390 for public use buildings (9 kN/m²). Regarding to vibrations, floors in an overhanging configuration with a length-to-depth ratio equal to 6 and a simply supported portion equal to four times the length of the overhanging portion, with total loads up to 9.0 kN/ m², both in multi-storey buildings for residential and office use, present a high comfort level. Consequently, the proposed timber-concrete composite (TCC) overhanging floor solution has demonstrated high stiffness and strength that make it a suitable alternative for the construction of high-performance lightweight floors in multi-storey buildings.
Palabras clave
Timber-concrete composite
Timber flooring systems
Mixed beams
Cantilever floors
 
Descripción
Financiado para a publicación en acceso aberto: Universidade da Coruña/CISUG
Versión del editor
https://doi.org/10.1016/j.engstruct.2023.116460
Derechos
Atribución-NoComercial-SinDerivadas 3.0 España
ISSN
0141-0296

Listar

Todo RUCComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasGrupo de InvestigaciónTitulaciónEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasGrupo de InvestigaciónTitulación

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso
Sherpa
OpenArchives
OAIster
Scholar Google
UNIVERSIDADE DA CORUÑA. Servizo de Biblioteca.    DSpace Software Copyright © 2002-2013 Duraspace - Sugerencias