Mostrar o rexistro simple do ítem

dc.contributor.authorCantonati, Marco
dc.contributor.authorCid, María
dc.contributor.authorRossi, Floriana
dc.contributor.authorLeira, Manel
dc.date.accessioned2023-09-11T15:28:42Z
dc.date.available2023-09-11T15:28:42Z
dc.date.issued2023-05-13
dc.identifier.citationCantonati, M.; Cid-Rodríguez, M.; Rossi, F.; Leira, M. A Simple and Inexpensive Method to Gain Diatom Absolute Abundances from Permanent Mounts in Hydrobiological and Paleoecological Research. Appl. Sci. 2023, 13, 6019. https://doi.org/10.3390/app13106019es_ES
dc.identifier.issn2076-3417
dc.identifier.urihttp://hdl.handle.net/2183/33467
dc.descriptionThis article belongs to the Special Issue Advances in Hydrogeologyes_ES
dc.description.abstract[Abstract] Here, we describe and discuss a method based on microscopical field of view (FOV) area to estimate diatom absolute abundances (densities or concentrations), and we statistically verify its reliability, also comparing it to another commonly used method (microspheres). To test the new method, we purposely performed replicate counts, both with the FOV and with the microsphere method, on both subfossil and recent material (samples) from mires. Intraclass correlation (ICC) revealed a high degree of agreement between the measurements obtained for the replicates with each of the two methods, suggesting that both are reliable for measuring diatom valve concentrations. However, the FOV consistently overestimated diatom absolute abundances, as compared to the microsphere method, and the ICC value used to assess the reliability of the two methods combined suggested that the two methods cannot be used interchangeably. The FOV method is relatively simple, has a lower cost, wider applicability, higher resolution, and warrants compatibility with existing datasets. However, there may also be drawbacks, such as the potential for sample distortion during the concentration process. Therefore, it is important to carefully evaluate the strengths and limitations of the different methods before adopting one for specific research or applied questions.es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.relation.urihttps://doi.org/10.3390/app13106019es_ES
dc.rightsAtribución 4.0 Internacionales_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectDiatomses_ES
dc.subjectAbsolute abundanceses_ES
dc.subjectMethodologyes_ES
dc.subjectMireses_ES
dc.subjectMicrosphereses_ES
dc.subjectFOVes_ES
dc.titleA Simple and Inexpensive Method to Gain Diatom Absolute Abundances from Permanent Mounts in Hydrobiological and Paleoecological Researches_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessinfo:eu-repo/semantics/openAccesses_ES
UDC.journalTitleApplied Scienceses_ES
UDC.volume13 (2023)es_ES
UDC.issue10es_ES
UDC.startPage6019es_ES
dc.identifier.doi10.3390/app13106019


Ficheiros no ítem

Thumbnail
Thumbnail

Este ítem aparece na(s) seguinte(s) colección(s)

Mostrar o rexistro simple do ítem