Análisis de movimiento mediante textil inteligente
View/ Open
Use this link to cite
http://hdl.handle.net/2183/31354
Except where otherwise noted, this item's license is described as Atribución-NoComercial-CompartirIgual 4.0 Internacional (CC BY-NC-SA 4.0)
https://creativecommons.org/licenses/by-nc-sa/4.0/deed.es
Collections
Metadata
Show full item recordTitle
Análisis de movimiento mediante textil inteligenteAlternative Title(s)
Smart garment for movement analysisAuthor(s)
Date
2022Citation
Delgado-Oleas, G., Avellar, L., Stefano-Filho, C., Frizera, A., Leal-Junior, A., Rocon, E. (2022) Análisis de movimiento mediante textil inteligente. XLIII Jornadas de Automática: libro de actas, pp.66-70 https://doi.org/10.17979/spudc.9788497498418.0066
Abstract
[Resumen] Este artículo presenta el desarrollo de un textil inteligente (smart garment) portátil dotado de 30 sensores de fibra óptica multiplexados que, a través de algoritmos de Inteligencia Artificial (IA), es capaz de clasificar de actividades de múltiples sujetos. Se evalúan seis actividades diarias: de pie, sentado, en cuclillas, brazos arriba y abajo, caminar y correr. El clasificador utilizado es el de k vecinos más cercanos y los resultados de 10 ensayos de todos los voluntarios presentaron una precisión de 94,00 (0,14) %. La cadencia y la frecuencia respiratoria se estimaron y compararon con los datos de una unidad de medición inercial ubicada en la parte posterior de la prenda. El error más alto fue del 2,22 %. El enfoque propuesto presentó la viabilidad para el reconocimiento de actividad y la extracción de parámetros relacionados con el movimiento, en el ámbito de los desarrollos en Healthcare 4.0. [Abstract] This paper presents the development of a wearable smart garment equipped with 30 multiplexed fiber optic sensors that, through Artificial Intelligence (AI) algorithms, can classify multiple subjects' activities.
Six daily activities are evaluated: standing, sitting, squatting, arms up and down, walking, and running. The classifier used is k-nearest neighbors, and results from 10 trials of all volunteers showed an accuracy of 94.00 (0.14)%. Cadence and respiratory rate were estimated and compared with data from an inertial measurement unit located on the back of the garment. The highest error was 2.22%. The proposed approach presented feasibility for activity recognition and extraction of motion-related parameters in the scope of Healthcare 4.0 developments.
Keywords
Healthcare
Textil inteligente
Análisis de movimiento
Smartgarment
Movement analysis
Textil inteligente
Análisis de movimiento
Smartgarment
Movement analysis
Editor version
Rights
Atribución-NoComercial-CompartirIgual 4.0 Internacional (CC BY-NC-SA 4.0)
https://creativecommons.org/licenses/by-nc-sa/4.0/deed.es
ISBN
978-84-9749-841-8