Skip navigation
  •  Inicio
  • UDC 
    • Cómo depositar
    • Políticas del RUC
    • FAQ
    • Derechos de autor
    • Más información en INFOguías UDC
  • Listar 
    • Comunidades
    • Buscar por:
    • Fecha de publicación
    • Autor
    • Título
    • Materia
  • Ayuda
    • español
    • Gallegan
    • English
  • Acceder
  •  Español 
    • Español
    • Galego
    • English
  
Ver ítem 
  •   RUC
  • Facultade de Enfermaría e Podoloxía
  • Investigación (FEP)
  • Ver ítem
  •   RUC
  • Facultade de Enfermaría e Podoloxía
  • Investigación (FEP)
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Ultrasound evaluation of intrinsic plantar muscles and fascia in hallux valgus : A case-control study

Thumbnail
Ver/Abrir
LopezLopez_Daniel_2016_Ultrasound_evaluation_intrinsic.pdf (445.3Kb)
Use este enlace para citar
http://hdl.handle.net/2183/30232
Atribución-SinDerivadas 3.0 España
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-SinDerivadas 3.0 España
Colecciones
  • Investigación (FEP) [507]
Metadatos
Mostrar el registro completo del ítem
Título
Ultrasound evaluation of intrinsic plantar muscles and fascia in hallux valgus : A case-control study
Autor(es)
López-López, Daniel
Calvo-Lobo, César
Garrido-Marín, Alejandro
Rodríguez Sanz, David
Palomo-López, Patricia
Romero Morales, Carlos
Sanz Corbalán, Irene
Fecha
2016-11
Cita bibliográfica
Lobo, César Calvo PT, PhDa,*; Marín, Alejandro Garrido PT, MScb; Sanz, David Rodríguez PT, DP, MScc; López, Daniel López DP, PhDd; López, Patricia Palomo DP, PhDe; Morales, Carlos Romero PT, PhDc; Corbalán, Irene Sanz DP, PhDf Ultrasound evaluation of intrinsic plantar muscles and fascia in hallux valgus, Medicine: November 2016 - Volume 95 - Issue 45 - p e5243 doi: 10.1097/MD.0000000000005243
Resumen
[Abstract] A cross-sectional area (CSA) and thickness reduction of the abductor hallucis (AbH) is shown in subjects with hallux valgus (HV). To date, other soft-tissue structures have not been researched in relation with HV. The aim of this study was to compare the CSA and thickness of the intrinsic plantar muscles and fascia (PF) between feet with and without HV. Therefore, a cross-sectional and case-control study was performed using B-mode with an iU22 Philips ultrasound system and a 5 to 17-MHz transducer. The CSA and thickness were measured for the AbH, flexor digitorum brevis (FDB) and flexor hallucis brevis (FHB), and also the thickness for the anterior, middle, and posterior PF portions. A convenience sample of 40 feet, 20 with HV and 20 without HV, was recruited from a clinical and research center. A multivariate regression analysis using linear regression was performed to evaluate the ultrasound imaging measurements (α = 0.05). Consequently, statistically significant differences were observed between the groups (P < 0.05) for the AbH and FHB thickness, and CSA reduction, and also the plantar fascia thickness increase in favor of the HV group. On the contrary, the FDB thickness and CSA did not show statistically significant differences (P ≥ 0.05). In conclusion, the CSA and thickness of the AbH and FHB intrinsic plantar muscles are reduced, whereas the thickness of the anterior, middle, and posterior PF portions are increased, in subjects with HV compared with those without HV.
Palabras clave
Anatomy
Anatomía
Cross-sectional
Transversal
Hallux valgus
Physical therapy modalities
Modalidades de terapia física
Ultrasonografía
Ultrasonography
 
Versión del editor
10.1097/MD.0000000000005243
Derechos
Atribución-SinDerivadas 3.0 España

Listar

Todo RUCComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasGrupo de InvestigaciónTitulaciónEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasGrupo de InvestigaciónTitulación

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso
Sherpa
OpenArchives
OAIster
Scholar Google
UNIVERSIDADE DA CORUÑA. Servizo de Biblioteca.    DSpace Software Copyright © 2002-2013 Duraspace - Sugerencias