Modeling the Natural Gas Knocking Behaviour Using Gas-Phase Infrared Spectra and Multivariate Calibration
Use este enlace para citar
http://hdl.handle.net/2183/30013
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-SinDerivadas 4.0 Internacional
Colecciones
- GI-QANAP - Artigos [30]
Metadatos
Mostrar el registro completo del ítemTítulo
Modeling the Natural Gas Knocking Behaviour Using Gas-Phase Infrared Spectra and Multivariate CalibrationAutor(es)
Fecha
2021-04-01Cita bibliográfica
Ponte, S., Andrade, J.M., Vázquez, C., Ferreiro, B., Cobas, C., Pérez, A., Rey, M., Vales, C., Pellitero, J., Santacruz, B., Muniategui, S., López-Mahía, P., Shu, B., Bettin, H., Klaus, D., Anders, B., Betz, M., Kühne, U., Meier, C., Eilts, P., 2021. Modeling the natural gas knocking behaviour using gas-phase infrared spectra and multivariate calibration. Journal of Natural Gas Science and Engineering 90, 103944. https://doi.org/10.1016/j.jngse.2021.103944
Resumen
[Abstract] To assess the knocking properties of natural gas (NG) when it is used as fuel for vehicles is vital to optimize the design and functioning of their motors. Analytical efforts in this field are needed as the engines used to define it empirically are not available anymore, and existent mathematical algorithms yield different accuracy. The hybridization of gas-phase infrared spectrometry and partial least squares multivariate regression is presented first time to address the determination of the methane number (MN) of NG samples. It circumvents the need for the previous knowledge of the NG composition required to apply dedicated equations. The use of true NG samples to develop the models is also quite new in the field. Proof-of-concept studies were made with synthetic spectra and, then, a collection of liquefied NG samples for which MN values were computed by the National Physics Laboratory algorithm (NPL) from their sample composition were used to develop operative models. Additional validation was made with a collection of synthetic standard mixtures prepared for two European projects (EMRP LNG II and EMPIR LNG III) whose service methane numbers (SMN) were measured with an engine. The FTIR-PLS approach yielded statistically unbiased predictions with average standard errors around 0.4% MN when compared to the NPL-MN and SMN values, and standard deviations of the means ca. 1% MN. The approach is fast, cost effective as it involves standard instrumentation, and can be considered compliant with the green chemistry principles.
Palabras clave
Methane number
Liquefied natural gas
Service methane number
Infrared spectrometry
Liquefied natural gas
Service methane number
Infrared spectrometry