Cone-beam CT-guided lung biopsies: results in 94 patients

Thumbnail
View/Open
GuliasSoidan_ConeBeam.pdf (5.618Mb)
Use this link to cite
http://hdl.handle.net/2183/27313
Creative Commons Attribution 4.0 International License (CC-BY 4.0)
Except where otherwise noted, this item's license is described as Creative Commons Attribution 4.0 International License (CC-BY 4.0)
Collections
  • Investigación (FFISIO) [481]
Metadata
Show full item record
Title
Cone-beam CT-guided lung biopsies: results in 94 patients
Author(s)
Gulías Soidán, Daniel
Crus-Sánchez, Nilfa Milena
Fraga-Manteiga, Daniel
Cao-González, Juan Ignacio
Balboa-Barreiro, Vanesa
González-Martín, Cristina
Date
2020-12-10
Citation
Gulias-Soidan D, Crus-Sanchez NM, Fraga-Manteiga D, Cao-González JI, Balboa-Barreiro V, González-Martín C. Cone-beam CT-guided lung biopsies: results in 94 patients. Diagnostics (Basel). 2020 Dec 10;10(12):1068.
Abstract
[Abstract] Background: The aim of this study was to evaluate the diagnostic capacity of Cone-Beam computed tomography (CT)-guided transthoracic percutaneous biopsies on lung lesions in our setting and to detect risk factors for possible complications. Methods: Retrospective study of 98 biopsies in 94 patients, performed between May 2017 and January 2020. To obtain them, a 17G coaxial puncture system and a Siemens Artis Zee Floor vc21 archwire were used. Descriptive data of the patients, their position at the time of puncture, location and size of the lesions, number of cylinders extracted, and complications were recorded. Additionally, the fluoroscopy time used in each case, the doses/area and the estimated total doses received by the patients were recorded. Results: Technical success was 96.8%. A total of 87 (92.5%) malignant lesions and 3 (3.1%) benign lesions were diagnosed. The sensitivity was 91.5% and the specificity was 100%. We registered three technical failures and three false negatives initially. Complications included 38 (38.8%) pneumothorax and 2 (2%) hemoptysis cases. Fluoroscopy time used in each case was 4.99 min and the product of the dose area is 11,722.4 microGy/m2. Conclusion: The transthoracic biopsy performed with Cone-Beam CT is accurate and safe in expert hands for the diagnosis of lung lesions. Complications are rare and the radiation dose used was not excessive.
Keywords
Lung
Transthoracic biopsy
Radiation
 
Editor version
https://dx.doi.org/10.3390/diagnostics10121068
Rights
Creative Commons Attribution 4.0 International License (CC-BY 4.0)
ISSN
2075-4418

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsResearch GroupAcademic DegreeThis CollectionBy Issue DateAuthorsTitlesSubjectsResearch GroupAcademic Degree

My Account

LoginRegister

Statistics

View Usage Statistics
Sherpa
OpenArchives
OAIster
Scholar Google
UNIVERSIDADE DA CORUÑA. Servizo de Biblioteca.    DSpace Software Copyright © 2002-2013 Duraspace - Send Feedback