Mostrar o rexistro simple do ítem

dc.contributor.authorDíaz González, Macarena
dc.contributor.authorMoura, Joaquim de
dc.contributor.authorNovo Buján, Jorge
dc.contributor.authorOrtega Hortas, Marcos
dc.date.accessioned2020-01-13T16:11:43Z
dc.date.available2020-01-13T16:11:43Z
dc.date.issued2019
dc.identifier.citationDíaz, Macarena, et al. Automatic wide field registration and mosaicking of OCTA images using vascularity information. Procedia Computer Science, 2019, vol. 159, p. 505-513.es_ES
dc.identifier.issn1877-0509
dc.identifier.urihttp://hdl.handle.net/2183/24596
dc.description.abstract[Abstract] Optical Coherence Tomography Angiography (OCTA) constitutes a novel ophthalmological image modality that is characterized for being a non-invasive capture technique that allows a profound analysis of the vascular characteristics of the eye fundus. Given the restricted field of view of the eye fundus that offers each scan, the specialists frequently capture several complementary images that may be simultaneously analyzed to offer a complete and accurate diagnosis of the patient. In this work, we propose a fully automatic method to register complementary OCTA images and provide compositions for the same patient, generating a wide field of representation that allows a simpler and more direct analysis than the traditional tedious manual procedures. To achieve this, we based our proposal in a robust combination of representative features that are filtered by an accurate identification of the main retinal vasculature. This way, given the characteristic high irregularity in the fundus of the OCTA images, we avoid many variable areas that may interfere in the registration process, restricting the analysis to the most representative and stable structure of this image modality, the main retinal vasculature. In particular, we use Speeded-Up Robust Features (SURF) algorithm to extract representative features in the main vascular region that is extracted using a method that combines the analysis of the Hessian matrix followed by an hysteresis threshold process. Then, using a K-NN model, we perform the registration of the resulting features from the different OCTA images to be analyzed. Finally, the Random sample consensus (RANSAC) method is exploited to produce the final target mosaic. The proposed method presented satisfactory results in the validation experiments, with accurate values for the MSE index of 1.2566 and 1.6725 pixels for the registration of paired images an mosaics, respectively.es_ES
dc.description.sponsorshipXunta de Galicia; ED431G/01es_ES
dc.description.sponsorshipXunta de Galicia; ED431C 2016-047es_ES
dc.description.sponsorshipThis work is supported by the Instituto de Salud Carlos III, Government of Spain and FEDER funds of the European Union through the DTS18/00136 research projects and by the Ministerio de Economía y Competitividad, Government of Spain through the DPI2015-69948-R research project. Also, this work has received financial support from the European Union (European Regional Development Fund - ERDF) and the Xunta de Galicia, Centro singular de investigación de Galicia accreditation 2016-2019, Ref. ED431G/01; and Grupos de Referencia Competitiva, Ref. ED431C 2016-047.
dc.language.isoenges_ES
dc.publisherElsevier BVes_ES
dc.relationinfo:eu-repo/grantAgreement/MICINN/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/DTS18%2F00136/ES/Plataforma online para prevención y detección precoz de enfermedad vascular mediante análisis automatizado de información e imagen clínica
dc.relationinfo:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2015-69948-R/ES/IDENTIFICACION Y CARACTERIZACION DEL EDEMA MACULAR DIABETICO MEDIANTE ANALISIS AUTOMATICO DE TOMOGRAFIAS DE COHERENCIA OPTICA Y TECNICAS DE APRENDIZAJE MAQUINA
dc.relation.urihttps://doi.org/10.1016/j.procs.2019.09.205es_ES
dc.rightsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)es_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectOptical Coherence Tomography Angiographyes_ES
dc.subjectRegistrationes_ES
dc.subjectMosaickinges_ES
dc.subjectSURFes_ES
dc.subjectRANSACes_ES
dc.subjectRetinal vascularityes_ES
dc.titleAutomatic Wide Field Registration and Mosaicking of OCTA Images Using Vascularity Informationes_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.rights.accessinfo:eu-repo/semantics/openAccesses_ES
UDC.journalTitleProcedia Computer Sciencees_ES
UDC.volume159es_ES
UDC.startPage505es_ES
UDC.endPage513es_ES
dc.identifier.doi10.1016/j.procs.2019.09.205
UDC.conferenceTitleProceedings of the 23rd International Conference KES2019es_ES


Ficheiros no ítem

Thumbnail
Thumbnail

Este ítem aparece na(s) seguinte(s) colección(s)

Mostrar o rexistro simple do ítem