Mostrar o rexistro simple do ítem

dc.contributor.authorBarge-Caballero, Eduardo
dc.contributor.authorVázquez Rodríguez, José Manuel
dc.contributor.authorEstévez-Loureiro, Rodrigo
dc.contributor.authorBarge-Caballero, Gonzalo
dc.contributor.authorRodríguez-Vilela, Alejandro
dc.contributor.authorCalviño-Santos, Ramón
dc.contributor.authorSalgado-Fernández, Jorge
dc.contributor.authorAldama López, Guillermo
dc.contributor.authorPiñón-Esteban, Pablo
dc.contributor.authorCampo-Pérez, Rosa
dc.contributor.authorRodríguez-Fernández, José Ángel
dc.contributor.authorVázquez-González, Nicolás
dc.contributor.authorMuñiz, Javier
dc.contributor.authorCastro-Beiras, Alfonso
dc.date.accessioned2016-11-25T10:27:55Z
dc.date.available2016-11-25T10:27:55Z
dc.date.issued2010
dc.identifier.citationBarge-Caballero E, Vázquez-Rodríguez JM, Estévez-Loureiro R, et al. Prevalencia, causas y pronóstico de las «falsas alarmas» al laboratorio de hemodinámica en pacientes con sospecha de infarto de miocardio con elevación del segmento ST. Rev Esp Cardiol. 2010;63(5):518-527es_ES
dc.identifier.issn0300-8932
dc.identifier.urihttp://hdl.handle.net/2183/17632
dc.description.abstract[Resumen] Introducción y objetivos. Determinar prevalencia, causas y pronóstico de las «falsas alarmas» al laboratorio de hemodinámica (FALH) en una red regional de angioplastia primaria. Métodos. Registro prospectivo de 1.662 pacientes remitidos para angioplastia primaria entre enero de 2003 y agosto de 2008. Se definió FALH como ausencia de lesión coronaria causal. Resultados. En 120 pacientes (7,2%; intervalo de confianza [IC] del 95%, 5,9-8,5) no se identificó ninguna lesión coronaria causal. De ellos, 104 (6,3%; IC del 95%, 5,1-7,4) recibieron un diagnóstico alternativo a IAMCEST, 91 (5,5%; IC del 95%, 4,3-6,6) no presentaron enfermedad coronaria significativa y 64 (3,8%; IC del 95%, 2,9-4,8) presentaron marcadores de daño miocárdico negativos. Los diagnósticos alternativos más frecuentes fueron: infarto con onda Q previo (18 casos), alteraciones inespecíficas del segmento ST (11), pericarditis (10) y discinesia apical transitoria (10). La mortalidad a 30 días fue similar en los pacientes con y sin lesión causal (el 5,8 frente al 5,8%; p = 0,99). La prevalencia de FALH fue discretamente superior entre los pacientes remitidos desde los servicios de urgencias de hospitales no intervencionistas sin evaluación previa por un cardiólogo que entre los remitidos por cardiólogos desde el servicio de urgencias del hospital intervencionista (el 9,5 frente al 6,1%; p = 0,02; odds ratio [OR] = 1,64; IC del 95%, 1,08-2,5). No observamos un exceso de FALH entre los pacientes remitidos por médicos de UVI Móviles-061 (7,2%; p = 0,51; OR = 1,37; IC del 95%, 0,79-2,37). Conclusiones. Hemos observado una prevalencia de FALH del 7,2% de acuerdo con el criterio de ausencia de lesión coronaria causal. Nuestros resultados indican que diferentes modelos de activación del laboratorio de hemodinámica podrían justificar discretas variaciones en la prevalencia de FALH.es_ES
dc.description.abstract[Abstract] Introduction and objectives. To investigate the prevalence, causes and outcome of catheterization laboratory false alarms (CLFAs) in a regional primary angioplasty network. Methods. A prospective registry of 1,662 patients referred for primary angioplasty between January 2003 and August 2008 was reviewed to identify CLFAs (i.e. when no culprit coronary lesion could be found). Results. No culprit coronary lesion could be identified in 120 patients (7.2%; 95% confidence interval [CI], 5.9- 8.5%). Of these, 104 (6.3%, 95% CI, 5.1-7.4%) had a discharge diagnosis other than ST-elevation myocardial infarction, 91 (5.5%; 95% CI, 4.3-6.6%) had no significant coronary disease, and 64 (3.8%; 95% CI, 2.9-4.8%) tested negative for cardiac biomarkers. The most frequent alternative diagnoses were: previous Q-wave myocardial infarction (18 cases), nonspecific ST-segment abnormalities (11), pericarditis (10) and transient apical dyskinesia (10). The 30-day mortality rate was similar in patients with and without culprit lesions (5.8% vs. 5.8%; P=.99). The prevalence of CLFAs was slightly higher in patients not previously evaluated by a cardiologist and referred from emergency departments in hospitals without catheterization laboratories than in those referred by cardiologists from emergency departments at hospitals with such facilities (9.5% vs. 6.1%; P=.02; odds ratio=1.64; 95% CI, 1.08-2.5). The prevalence of CLFAs was not significantly higher in patients referred by physicians with out-of-hospital emergency medical services (7.2%; P=.51; odds ratio=1.37; 95% CI, 0.79-2.37). Conclusions. The prevalence of CLFAs was 7.2%, with the criterion of no culprit coronary lesion. Our findings suggest that different patterns of referral to catheterization laboratories could account for small variations in the prevalence of CLFAs.es_ES
dc.language.isospaes_ES
dc.publisherSociedad Española de Cardiologíaes_ES
dc.relation.urihttp://dx.doi.org/10.1016/S0300-8932(10)70113-5es_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Españaes_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subjectInfarto de miocardioes_ES
dc.subjectAngioplastiaes_ES
dc.subjectDiagnósticoes_ES
dc.subjectCoronariografíaes_ES
dc.subjectMyocardial infarctiones_ES
dc.subjectAngioplastyes_ES
dc.subjectDiagnosises_ES
dc.subjectCoronary angiographyes_ES
dc.titlePrevalencia, causas y pronóstico de las «falsas alarmas» al laboratorio de hemodinámica en pacientes con sospecha de infarto de miocardio con elevación del segmento STes_ES
dc.title.alternativePrevalence, etiology and outcome of catheterization laboratory false alarms in patients with suspected ST-elevation myocardial infarctiones_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessinfo:eu-repo/semantics/openAccesses_ES
UDC.journalTitleRevista Española de Cardiologíaes_ES
UDC.volume63es_ES
UDC.issue5es_ES
UDC.startPage518es_ES
UDC.endPage527es_ES


Ficheiros no ítem

Thumbnail
Thumbnail

Este ítem aparece na(s) seguinte(s) colección(s)

Mostrar o rexistro simple do ítem