Potentiometric characterisation of cyclodextrin inclusion complexes of local anaesthetics
Use this link to cite
http://hdl.handle.net/2183/14120Collections
- GI-CS - Artigos [11]
Metadata
Show full item recordTitle
Potentiometric characterisation of cyclodextrin inclusion complexes of local anaestheticsDate
2011-09Citation
Isabel Brandariz & Emilia Iglesias (2011) Potentiometric characterisation of cyclodextrin inclusion complexes of local anaesthetics, Supramolecular Chemistry, 23:9, 607-613, DOI: 10.1080/10610278.2011.593632
Abstract
The complexation of several local anaesthetics by β and γ-cyclodextrins was studied by potentiometry with glass electrode. Tetracaine and dibucaine complexation constants were determined at 25°C in the presence of 0.1 M of NaCl. It was found that prilocaine and lidocaine complexes cannot be detected.
Keywords
Inclusion complexes
Cyclodextrin
Potentiometric technique
Local anaesthetics
Cyclodextrin
Potentiometric technique
Local anaesthetics
Editor version
Rights
This is an Accepted Manuscript of an article published by Taylor & Francis Group in Supramolecular Chemistry on Volume 23, Issue 9, September 2011, available online at: http://www.tandfonline.com/10.1080/10610278.2011.593632
ISSN