Skip navigation
  •  Inicio
  • UDC 
    • Cómo depositar
    • Políticas del RUC
    • FAQ
    • Derechos de autor
    • Más información en INFOguías UDC
  • Listar 
    • Comunidades
    • Buscar por:
    • Fecha de publicación
    • Autor
    • Título
    • Materia
  • Ayuda
    • español
    • Gallegan
    • English
  • Acceder
  •  Español 
    • Español
    • Galego
    • English
  
Ver ítem 
  •   RUC
  • Publicacións UDC
  • Congresos e cursos UDC
  • International Congress Biotechniques for Air Pollution Control
  • International Congress on Biotechniques for Air Pollution Control ( 2º. 2007. A Coruña)
  • Ver ítem
  •   RUC
  • Publicacións UDC
  • Congresos e cursos UDC
  • International Congress Biotechniques for Air Pollution Control
  • International Congress on Biotechniques for Air Pollution Control ( 2º. 2007. A Coruña)
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

High throughput biofiltration for odour control at water purification plant

Thumbnail
Ver/Abrir
CC-92_art_5.pdf (248.5Kb)
Use este enlace para citar
http://hdl.handle.net/2183/12859
Colecciones
  • International Congress on Biotechniques for Air Pollution Control ( 2º. 2007. A Coruña) [57]
Metadatos
Mostrar el registro completo del ítem
Título
High throughput biofiltration for odour control at water purification plant
Autor(es)
Zhukov, Vitaly
Vepritzky, Andrey
Mitin, Leonid
Popov, Vladimir O
Fecha
2007
Cita bibliográfica
Biotechniques for Air Pollution Control II, 2007: 59-66. ISBN: 978-84-9749-258-4
Resumen
[Abstract] A high throughput trickling biofilter for odour control was designed basing on the principles of biotrickling filter technology developed in Moscow Bakh Institute of Biochemistry. All the necessary blocks except a fan: temperature and humidity control unit, a biofilter bed, an irrigation system, a control block and display unit are combined within one compact biofiltration module – a standard container 6000x2400x2400 mm. The plant is thermo-insulated that enables outdoor installation. The biofilter is easily scaled up by adding extra filtration beds. A typical biofiltration module rated for 5,000-10,000 m3/h has a contact time of 3-6 s (biofilter bed total volume – 10.5 m3) and a maximum footprint of 14.5 m2. After extensive pilot plant studies the first 5000 m3/h trickling biofilter easily scalable to 20000 m3/h was installed at Moscow Water Works in spring 2007 to control odour emissions - hydrogen sulfide, mercaptanes and other malodorous volatile organic compounds in up to 60 mg/m3 concentration. The performance results of the industrial biofilter are discussed
ISBN
978-84-9749-258-4

Listar

Todo RUCComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasGrupo de InvestigaciónTitulaciónEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasGrupo de InvestigaciónTitulación

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso
Sherpa
OpenArchives
OAIster
Scholar Google
UNIVERSIDADE DA CORUÑA. Servizo de Biblioteca.    DSpace Software Copyright © 2002-2013 Duraspace - Sugerencias